LA 17PS - LA 26PS
11 Device Information
1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices
and heating components
2.2
Installation Location
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow
Air
3.2
Temperature spread
of heating water
3.3
Heat output / COP
3.4
Sound power level
3.5
Sound pressure level at a distance of 10 m
(air outlet side)
3.6
Heating water flow
with an internal pressure differential of
3.7
Air flow rate
3.8
Refrigerant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions
4.2
Device connections to heating system
4.3
Weight of the transportable unit(s) incl. packing
5
Electrical connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current A2 W35 / cos
5.4
5.5
max. power consumption of compressor protection
(per compressor)
6
Complies with the European safety regulations
7
Additional model features
7.1
Defrosting
Type of defrosting
Defrosting tray included
7.2
Heating water in device protected against icing
7.3
Performance levels
7.4
Controller internal/external
1. See operating limits diagram
2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature
and 55 °C heating water flow temperature.
3. Operation with 1 compressors
4. Operation with 2 compressors
5. See CE declaration of conformity
6. The heat circulating pump and the heat pump manager must always be ready for operation.
EN-10
1
°C / °C
°C
at A7 / W35
2
at A-7 / W35
kW / ---
2
at A-7 / W45
kW / ---
2
at A2 / W35
kW / ---
2
at A7 / W35
kW / ---
2
at A7 / W45
kW / ---
2
at A10 / W35
kW / ---
dB(A)
dB(A)
m³/h / Pa
m³/h
type / kg
H x W x L cm
Inch
kg
V / A
2
A2 W35
kW
A
A / ---
W
6
452159.66.04 · FD 9202
LA 17PS
LA 22PS
IP 24
Outdoors
Outdoors
Up to 65 / above 18
Up to 65 / above 18
-20 to +35
-20 to +35
9.3
5.0
9.5
3
6.7 / 2.5
6.4 / 2.4
7.7 / 2.4
4
11.4 / 2.6
10.8 / 2.5
13.6 / 2.6
3
6.0 / 2.2
4
10.3 / 2.2
3
8.7 / 3.2
8.3 / 3.0
10.6 / 3.1
4
14.5 / 3.1
14.3 / 3.0
16.7 / 3.1
3
10.1 / 3.6
9.6 / 3.4
12.6 / 3.8
4
17.3 / 3.5
16.6 / 3.4
22.0 / 3.8
3
9.3 / 2.9
4
16.1 / 2.9
3
11.8 / 4.1
11.4 / 4.1
13.7 / 4.2
4
19.6 / 3.8
19.2 / 3.8
23.4 / 4.0
64
37
1.6 / 2900 3.0 / 10000 2.0 / 4500 3.5 / 13800 2.2 / 3100 3.8 / 8900
5500
R290 / 1.8
R290 / 2.2
157 x 155 x 85
171 x 168 x 100
G 1 1/4'' external
G 1 1/4'' external
330
400 / 20 T
400 / 20 T
4.74
4.76
5.4
23
8.6 / 0.8
8.6 / 0.8
9.8 / 0.8
5
Automatic
Automatic
Hot gas
Hot gas
Yes (heated)
Yes (heated)
Yes
2
External
External
LA 26PS
IP 24
IP 24
Outdoors
Up to 65 / above 18
-20 to +35
5.0
9.4
5.0
7.5 / 2.3
8.7 / 2.4
8.4 / 2.2
13.1 / 2.5
14.4 / 2.6
13.9 / 2.5
7.0 / 2.2
7.8 / 2.3
12.5 / 2.3
13.3 / 2.3
10.5 / 3.0
11.7 / 3.1
11.5 / 3.0
16.5 / 3.0
18.8 / 3.1
18.6 / 3.0
12.0 / 3.6
13.7 / 3.6
13.3 / 3.5
21.1 / 3.5
24.0 / 3.7
22.9 / 3.5
11.3 / 3.0
12.5 / 2.9
20.5 / 3.0
21.6 / 3.0
13.5 / 4.1
15.0 / 4.1
14.7 / 4.0
23.2 / 3.9
26.2 / 4.0
25.9 / 4.0
68
68
41
41
8000
8000
R290 / 2.5
171 x 168 x 100
G 1 1/4'' external
360
371
400 / 25 T
5.5
6.1
6.2
25
30
9.9 / 0.8
11.1 / 0.8
11.2 / 0.8
35
5
5
Automatic
Hot gas
Yes (heated)
Yes
Yes
2
2
External
www.dimplex.de