Other Technical Data; Energy Efficiency - Progress PAG6430 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Other technical data

TOTAL POWER:
Electric supply:
Appliance category:
Gas connection:
Appliance class:
Bypass diameters
BURNER
Triple Crown
Semi-rapid
Auxiliary
Gas burners for NATURAL GAS G25 25 mbar
BURNER
Triple Crown
Semi-rapid
Auxiliary
Gas burners for LPG G30/G31 30/30 mbar
BURNER
Triple Crown
Semi-rapid
Auxiliary

ENERGY EFFICIENCY

Product information according to EU 66/2014
Model identification
Type of hob
Gas original:
Gas replacement:
230 V ~ 50 Hz
II2L3B/P
R 1/2"
3
Ø BYPASS 1/100 mm
56
32
28
NORMAL POWER
kW
4,0
2,0
1,0
NORMAL
MINIMUM
POWER kW
POWER kW
4,0
1,4
2,0
0,45
1,0
0,33
G25 (2L) 25 mbar = 9 kW
G30/G31 (3B/P) 30/30 mbar = 654 g/h
MINIMUM POWER
kW
1,4
0,45
0,33
INJECTOR
MARK 1/100
mm
98
71
50
Progress 29
INJECTOR MARK
1/100 mm
147
100
071
NOMINAL GAS
FLOW g/h
291
145
73
PAG6430E-N
Built-in hob

Publicité

Table des Matières
loading

Table des Matières