Injectors replacement

1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
3. With a socket spanner 7 remove the
injectors and replace them with the
ones which are necessary for the type
of gas you use (see table in "Technical
Information" chapter).
4. Assemble the parts, follow the same
procedure backwards.
5. Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied with
the appliance.
If the supply gas pressure is changeable or
different from the necessary pressure, you
must fit an applicable pressure adjuster on
the gas supply pipe.

Adjustment of minimum level

To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the
bypass screw position (A).
A
5. If you change:
• from natural gas G25 25 mbar to
liquid gas, fully tighten the bypass
screw in.
• from liquid gas to natural gas G25
25 mbar, undo the bypass screw
approximately 1/4 of a turn (1/2 of a
turn for Triple Crown burner).
WARNING! Make sure the
flame does not go out when you
quickly turn the knob from the
maximum position to the
minimum position.
Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
• This appliance is supplied with a mains
cable and a plug.
• Always use a correctly installed
shockproof socket.
• Make sure that there is an access to the
mains plug after the installation.
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• There is a risk of fire when the appliance
is in connection with an extension cable,
an adapter or a multiple connection.
Make sure that the ground connection
agrees with the standards and
regulations.
• Do not let the power cable to heat up to
a temperature higher than 90° C.
Make sure that you connect the
blue neutral cable to the terminal
with a letter "N" on it. Connect
the brown (or black) phase
cable to the terminal which has
a letter "L". Keep the phase
cable connected at all times.

Connection cable

To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-F T90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth wire
must be approximately 2 cm longer than
the brown (or black) phase wire.
Progress 27