S-idx
Designation
0x2025
0x00
Input analog
– overcurrent
0x01
Overcur-
rent IN00,
IN01,IN02
und IN03
0x2030
0x00
Input resistor
0x01
Resistance
IN04
0x02
Resistance
IN05
0x03
Resistance
IN06
0x04
Resistance
IN07
0x2040
0x00
System supp-
ly voltage
VBBS
0x01
VBBS
0x2041
0x00
Output supp-
ly voltage
0x01
VBB2
0x2050
Device tem-
perature
0x20F0
Node ID
0x20F1
Node ID
0x20F2
Baud rate
124
Data type
Default
ro
USINT
1
ro
USINT
0
ro
USINT
4
ro
UINT
0
ro
UINT
0
ro
UINT
0
ro
UINT
0
ro
USINT
1
ro
USINT
0
ro
USINT
1
ro
UINT
0
ro
UINT
0
rw
USINT
125
rw
USINT
125
rw
USINT
3
Details
Largest sub-index supported
0 = normal
channels (bit coded)
1 = overcur-
0b---- ---X = IN00
rent
0b---- --X- = IN01
0b---- -X-- = IN02
0b---- X--- = IN03
Largest sub-index supported
0...30 000
IN04 resistance
[Ohms]
0...30 000
IN05 resistance
[Ohms]
0...30 000
IN06 resistance
[Ohms]
0...30 000
IN07 resistance
[Ohms]
Largest sub-index supported
VBBS voltage [mV]
Largest sub-index supported
VBB2 voltage [mV]
temperature [°C]
1...125
node ID
[!] value(0x20F0) !=
value(20F1)
1...125
node ID
[!] value(0x20F0) !=
value(20F1)
baud rate
[!] value(0x20F2) != value(20F3)
0
1000 kBit/s
1
800 kBit/s
2
500 kBit/s
3
250 kBit/s
4
125 kBit/s
5
100 kBit/s
6
50 kBit/s
7
20 kBit/s

Publicité