If necessary, return control head and system to normal state
(switching position, power supply).
Close the housing.

12.2. Teach-Reset

Depress the Teach-In button (T1+T2) for ca. 2.5 sec.
(optical feedback: Blinking in the fault color)

12.3. Autotune

Autotune functions and Autotune sequences - see operating
instructions.
12.4. LED - Color Assignments
S1 -
green, continuously lit,
S2 -
yellow, continuously lit,
S3 -
green, continuously flashing (250 ms/250 ms)
(Delivered state of the DIP switches: 0000)
It is possible to set different color combinations with the help
of DIP switches - see the manual, chapter „Setting the color
combinations".
In the event of a fault or in various states, the LED's flash in different
flashing patterns - see the manual, chapter „Blinking pattern &
fault signaling".
If a valve has several overlapping states, a priority list of feedback
signal is valid - see the manual, chapter „Signal priorities".
All manuals and user guides at all-guides.com
Type 8681

Start-up

13. START-UP
WARNING!
Risk of injury from improper operation!
Improper operation may cause injury and damage to the
device and its environment.
• Before starting-up must be ensured that the contents
of the manual operator is known and understood.
• The safety instructions and the intended use must be
followed.
• Only adequately trained personnel should take the
plant / the device in operation.
Assembly of the control head type 8681.
Pneumatic and electrical installation.
Setting the position measuring system (Teach-In).
After assembly, installation and setting of the position measuring system
according to the operating instructions the control head is ready for
operation.