Do not use the battery charger for more than 48 hours at one
charge. If the battery is completely discharged, start the unit
per the "Starting Pull Start Engines" section and recharge the
battery by running the unit.
Figure 18 - Battery Charger Jack
BATTERY
CHARGER
INPUT

3.1 PERFORMING SCHEDULED MAINTENANCE

It is important to perform service as specified in the Maintenance
Schedule for proper generator operation, and to ensure that the
generator complies with the applicable emission standards for the
duration of its useful life. Service and repairs may be performed by
any capable person or repair shop. Additionally, emissions critical
maintenance must be performed as scheduled in order for the
Emissions Warranty to be valid. Emissions critical maintenance
consists of servicing the air filter and spark plugs in accordance
with the Maintenance Schedule.

3.2 MAINTENANCE SCHEDULE

Follow the calendar intervals. More frequent service is required
when operating in adverse conditions noted below.
Check Oil Level
Change Oil and Oil Filter‡
Check Valve Clearance
Service Air Filter
Replace Spark Plug
Clean Spark Arrestor Screen
‡ Change oil after first 30 hours of operation then every season.
* Change oil and oil filter every month when operating under heavy load or in high
temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter
parts if they cannot be adequately cleaned.
***
Check valve clearance and adjust if necessary after first 50 hours of
operation and every 100 hours thereafter.
NOTE:
At Each Use
*Every 100 hours or Every Season
***Every Season
** Every 200 hours or Every Season
Every Season
Every 100 hours or Every Season

3.3 PRODUCT SPECIFICATIONS

3.3.1 GENERATOR SPECIFICATIONS

3.6kW
Rated Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6kW
Surge Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5kW
Rated AC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120/240
Rated Max AC Load
Current @ 240V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Amps**
Current @120V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Amps**
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz @3600 RPM
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Phase
6.5 kW
Rated Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5kW**
Surge Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.13kW**
Rated AC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120/240
Rated Max AC Load
Current @ 240V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27.1 Amps**
Current @120V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54.2 Amps**
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz @3600 RPM
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Phase
8.0 kW
Rated Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.0kW**
Surge Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10kW**
Rated AC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120/240
Rated Max AC Load
Current @ 240V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33.3 Amps**
Current @120V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66.7 Amps**
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz @3600 RPM
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Phase
10.0 kW
Rated Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10kW**
Surge Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12kW**
Rated AC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120/240
Rated Max AC Load
Current @ 240V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41.7 Amps**
Current @120V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83.3 Amps**
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz @3600 RPM
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Phase
** Maximum wattage and current are subject to, and limited by, such factors
as fuel Btu content, ambient temperature, altitude, engine condition, etc..
Maximum power decreases about 3.5% for each 1,000 feet above sea level;
and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F)
ambient temperature.

3.3.2 ENGINE SPECIFICATIONS

3.6kW
Displacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216.5cc
Spar Plug Type. . . . . . . . . . . . . . . . . . . Champion RC14YC or Equivalent
Spark Plug Gap . . . . . . . . . . . . . . . . . . . . . . . . . . .0.030 inch (0.76mm)
Gasoline Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 U.S. Gallons
Oil Type . . . . . . . . . . . . . . . . . . See Chart in "Adding Engine Oil" Section
Oil Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . w/Filter Change = 0.8 Qts
Run Time (50% Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.5 hours
Class I Emission Certified

Maintenance

w/out Filter Change = 0.5 Qts
15
15