Operation
21. Oil Fill – Add oil here.
22. Air Filter – Filters intake air as it is drawn into the engine.
23. Recoil Starter (3.6, 6.5 & 8kW) - Use to start engine
manually.
24. Muffler – Quiets the engine.
25. Spark Arrestor – Reduces fire hazards by containing sparks.
26. Grounding Lug – Ground the generator to an approved earth
ground here. See "Grounding the Generator" for details.
27. Handles – Pivot and retract for storage. Press the spring-
loaded button to move handles.
28. Fuel Tank – See generator Specifications for tank capacity.
29. Gas Cap – Fuel fill location.
30. Fuel Gauge – Shows fuel level in tank.
31. Battery (6.5, 8 & 10kW) - Powers the electric starter motor.
32. Battery Charger Input (6.5, 8 & 10kW) - This receptacle
allows the capability to recharge the battery from the adaptor
plug charger.
33. Lifting Device – use to lift and store the generator after use.
See Lifting Safety notes in the beginning of this manual.
34. Fuel Shut Off – Valve between fuel tank and carburetor.
35. Fuse (10kW ONLY) - This 5 Amp fuse protects the starting
circuit from overload.
220cc Engine for
3.6kW Model
8
Figure 8 - Generator Controls
410cc Engine for
6.5 & 8kW Models

2.2 HOURMETER

The Hourmeter tracks hours of operation for scheduled
maintenance:
There will be a "CHG OIL" message every 100 hours. The message
will flash one hour before and one hour after each 100 hour
interval, providing a two hour window to perform service.
This message will actually begin flashing at 99 hours and disable
itself at 101 hours again, providing a two hour window to perform
the service.
Every 200 hours the "SVC" icon on the lower left hand corner of
the display will flash. The message will flash one hour before and
one hour after each 200 hour interval providing a two hour window
to perform service.
When the hour meter is in the Flash Alert mode, the maintenance
message will always alternate with elapsed time in hours and
tenths. The hours will flash four times, then alternate with the
maintenance message four times until the meter resets itself.
• 100 hours - CHG OIL — Oil Change Interval (Every 100 hrs)
• 200 hours - SVC — Air Filter Interval (Every 200 hrs)
530cc Engine for
10kW Model