5. Mechanical installation
5.1 Mounting on the wall
Mount the unit on a surface. The cable glands must
face downwards.
CAUTION
The product can fall down
Minor or moderate personal injury
Make sure to use screws that fit into
the unit and support its weight.
All cable screens must be connected
to earth. If it is not possible to use
cable clamps, the stripped part of the
cable screen must be as short as
possible to reduce the impedance at
high frequencies.
The cable glands must face
downwards.
1. Loosen the screws and remove the front cover.
2. Drill holes in the surface.
2
4
3. Insert wall plugs, if applicable.
4. Fit the four screws in the mounting holes and
3
Pos. Dimensions [mm] (inch)
1
115 (4.53")
2
91 (3.58")
3
ø4.5 (0.18")
4
81.5 (3.21")
cross-tighten the screws, 1.25 Nm.