5
-
C
D
A
B
fig. 2
A
MAINS SUPPLY
B
DISCHARGE DUCTS
C
PROTECTION SWITCH
D
PURIFIER
E
DRIP BOWL
F
POWER CABLE
Caution! The appliance is not suitable for installation
in areas where a water jet can be used.
Before proceeding with installation check that:
1 there are no bumps, signs of knocks or deformities.
2 there are no damp patches or marks which could lead
one to assume that the packaging has been exposed to
the elements
3 there are no signs of tampering
Once one is satisfied that transportation has been correctly
effected proceed with installation.
Proceed with installation following the instructions according
to the sequence as described below.
N.B. The least height of the support's top must be 110cm.
(The higher surface of the appliance shall however be at
least 1,5 m from the ground level)
INSTALLATION
E
F
5.1
Water connection
Important: The machine must be supplied with
water of over 8°F hardness.
The installation of a water softener is recommended for the
machine water supply.
Check that the water mains to which connection is to be
made supplies drinking water.
- Connect purifier (D) to the water mains (A).
NB: before connecting the purifier to the machine,
wash out thoroughly until the water becomes clear,
then proceed to connect the purifier to the machi-
ne.
- Connect the drain cup (E) to the drainage pipe (B)
- Should the mains pressure be higher than 0,5 MPa a
pressure reducer balanced for high pressure should be
installed (device in which any mains pressure increase
does not effect the output pressure).
Should the machine be moved to a different place, the fitting
unit must be replaced with a new one.
5.2
Electrical connection
Important ! Before proceeding with electrical
connection it is necessary to check to ensure that
the voltage rating corresponds with that indicated
on the CE plate and on the connection plate on the
power supply cable.
The appliance shall be placed so that the plug is easily
accessible.
Check to ensure that the electrical supply line is able to
support the machine load (see chap. 4 – technical features
table).
Connect to an earthing socket which complies with current
legislation.
Check that the power supply cable is efficient and that it
complies with national and European safety standards.
The user must undertake to power the machine protecting
the power line using a suitable safety switch (cut-out) that
complies with the legislation in force in the actual country
itself.
Connect the power cable (F) to the electric line using a
plug, or in the case of fixed installation, using a multi-polar
switch (C) for mains separation, with a contact distance of
at least 3 mm.
For voltage change refer to the diagram shown on the ge-
neral mains switch box.
The yellow-green coloured cable MUST be connected to the
room's earthing system.