AXC-2000BX
Order Number 18.4540
ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS
HD Surveillance Camera
These instructions are intended for installers of video
surveillance systems. Please read the instructions
carefully prior to installation and keep them for later
reference.
1
Applications
This high-resolution colour camera is specially designed for
use in video surveillance systems (CCTV). The video formats
HD-TVI, HD-CVI and AHD support transmission of high-
resolution analog video signals (1080p) via standard coaxial
cables with a maximum length of 300 m. Alternatively, the
video signal output can be switched to composite video
signal (CVBS). The camera features include automatic white
balance, automatic day/night switching with infrared filter,
digital noise suppression and other functions to be config-
ured via OSD menu.
2
Important Notes
The camera corresponds to all relevant directives of the EU
and is therefore marked with
.
•
The camera is suitable for indoor use only. For outdoor
applications, install the camera in a weatherproof housing.
•
Protect the camera against dust, humidity and heat (ad-
missible ambient temperature range: –20 °C to +50 °C).
•
For cleaning only use a dry, soft cloth; never use water
or chemicals.
•
No guarantee claims for the camera and no liability for
any resulting personal damage or material damage will
be accepted if the camera is used for other purposes than
originally intended, if it is not correctly installed, or if it is
not repaired in an expert way.
If the camera is to be put out of operation defini-
tively, take it to a local recycling plant for a disposal
which is not harmful to the environment.
3
Lens
A lens with DC voltage-controlled iris (DC lens) or a lens with
manual iris adjustment can be used.
MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany
CAUTION
Protect the image sensor chip and the
lens assembly against dust and impu-
rities and never touch them with your
fingers.
1) Remove the protective cap.
2) Screw the lens onto the thread (2); C mount lenses or
CS mount lenses may be used.
3) When using a lens with a DC voltage-controlled iris,
connect this lens to the jack (5) on the side of the camera.
☞
The jack has the following pin configuration (
Damp:
➀
= −
➁
= +
Drive:
➂
= +
➃
= −
4
Installation
1) Make a test run first to find the best mounting location.
Then fasten the camera, using the thread in the base (3).
For suspended installation, install the base on the upper
side of the camera housing.
2) Connect the BNC jack VIDEO (6) to the input of a video
recorder (e. g. AXR series from MONACOR) or to the
input of a monitor.
The output can be switched to the desired signal format.
Keep the control buttons (7) pressed (for approx. 5 sec-
onds) for the following special functions:
= composite output signal
= AHD output signal
= HD-TVI output signal
= HD-CVI output signal
3) Connect a regulated 12 V DC power supply unit with a
permanent rating of 150 mA (e. g. PSS-1210DC) to the
plug-in screw terminals (8). An adapter for low-voltage
plugs 5.5 / 2.1 mm (outside/inside diameter) is provided
with the camera. The power indicator (9) will light up.
4) Switch on the video recorder and the monitor connected
and align the camera by means of the image on the
monitor. Adjust the focus at the lens. For a lens with
manually adjustable iris, adjust this iris to optimum image
display (depth of focus and brightness). If the image is not
clear even though the focus has been adjusted correctly,
readjust the mechanical focus for the lens by means of
the adjustment ring (1): Loosen the two setscrews (4)
with the hex key supplied; once the adjustment has been
made, retighten the setscrews.
figure):
1 2 3
5
Settings via OSD Menu
The camera settings can be changed by means of an OSD
menu which is operated via control buttons (7) or via PTZ
remote control from the video recorder. The remote control
is made by means of the COC protocol via the video cable.
To activate the OSD menu, press the middle button
send the control command "Iris +" at the video recorder or
call up "Preset 95". The main menu will appear:
MAIN MENU
1. LENS
MANUAL
↲
2. EXPOSURE
3. BACKLIGHT
OFF
↲
4. DAY&NIGHT
AUTO
↲
5. NR
↲
6. SPECIAL
↲
7. ADJUST
↲
8. EXIT
SAVE&END
To select a menu item, use the arrow keys
commands for the vertical movement (Tilt). To change the
value or to select an option, use the arrow keys
control commands for the horizontal movement (Pan). When
↲
the symbol
appears behind a menu item or an option, the
middle button
or the command "Iris +" (corresponding
to "Enter") can be used to call up a submenu or to activate
a function.
All setting options can be found in the table on the back
of these instructions. These instructions refer to the preset
English menu; to change the menu language, go to
↲
.
CIAL
2. LANGUAGE
Copyright
by MONACOR INTERNATIONAL. All rights reserved.
©
VIDEO
4
5
6
7
To exit the menu, select, in the line
↲ (to save the changes) or
SAVE&END
the changes) and then confirm with the middle button
or with "Iris +".
To reset all settings to the factory settings, select the option
↲ in the line
and then confirm with the middle
RESET
EXIT
(7) or
button
or with "Iris +". The menu language selected will
remain the same after a reset.
6
Specifications
Image sensor: . . . . . . . . . . .CMOS chip, 8.5 mm (1⁄3 ")
Number of pixels: . . . . . . . .1920 × 1080 max.
Resolution: . . . . . . . . . . . . .1080P/25
Colour modulation system: .PAL/NTSC
Electronic shutter: . . . . . . . .1⁄50 – 1⁄50 000 s
or make control
Video output: . . . . . . . . . . .1 V (pp) / 75 Ω
Power supply: . . . . . . . . . . . ⎓ 12 V, 150 mA
or make
Ambient temperature: . . . .–20 °C to +50 °C
Dimensions: . . . . . . . . . . . .70 × 60 × 150 mm
Weight: . . . . . . . . . . . . . . .300 g
6. SPE-
Subject to technical modification.
A-1776.99.03.08.2018
POWER
DC 12 V
+ −
8
9
, the option
EXIT
↲ (to cancel
NOT SAVE