INSTALLATION
6.1.4 Factory-supplied components
Accessory
Image
Flexible water
pipe (1")
M10 bolts
Gaskets
Instruction
manual
Declaration of
-
conformity
?
N O T E
•
The previous accessories are supplied inside the packing assembly
(in the accessory box).
•
Additional refrigerant piping (field supplied) for connections to indoor
unit needs to be available.
•
If some of these accessories are not packed with the unit or any
damage to the unit is detected, please contact your dealer.
6.1.5 DHWT main parts (Descriptions)
Nº
Part
1
Front cover
2
Left cover
3
Right cover
4
DHW outlet (G3/4" male)
5
Unit controller
6
DHW inlet (G 3/4" male)
1
2
10
8
9
12
PMML0344B rev.2 - 01/2021
Qty.
Purpose
Heating coil pipes (for
2
connection between indoor
unit and DHWT)
To fix the tank to the indoor
4
unit
4 x1" for the heating coil pipes
4+2
2 x 3/4" for the DHW
connection
Basic instructions for the
1
installation of the device.
1
-
Nº
Part
7
Handles
8
Heating coil inlet (G1" male)
9
Heating coil outlet (G1" male)
10
"Inspection" hatch
11
DHWT electric heater
12
LCD support
3
4
5
6
7
7
12
11
6.1.6 Flexible water coil pipes considerations
Process for coil pipes connection (to avoid leakage).
1 Put a gasket inside the nut.
a)
Nut
Gasket
c)
2 Check that the nut turns free.
3 Be sure that the tube is aligned with the connection.
4 IMPORTANT! Ensure that the gasket is in contact and it is
seating uniformly with the connection.
5 By hand, rotate smoothly the nut and screw it into the
connection. The screwing may be easy and it should not
offer too much resistance, so if that happens, loosen the nut
and check that the pipe and the gasket position are correct
and proceed again with point 3 and 4.
6 With a spanner, finish the screwing process of the nut until
firm but without damaging the gasket.
?
C A U T I O N
• Always bend the water tubes with a radius > 90 mm.
• The tube will not spring back.
• Don't install the stainless steel tube in a twisted position.
• Don't bend these stainless steel tube more often than
required to avoid breaking it.
b)
R > 90 mm