schmalz RECB MATCH Notice D'utilisation page 87

Table des Matières

Publicité

Coding of IO-Link Events
Extended Device Status ID
(= IO-Link Event Code)
dec
hex
hex
0
0x0000
0x10
20736
0x5100
0x42
20752
0x5110
0x42
20754
0x5112
0x42
6162
0x1812
0x42
4096
0x1000
0x42
36096
0x8D00
36097
0x8D01
36112
0x8D10
36113
0x8D11
36128
0x8D20
36129
0x8D21
36144
0x8D30
36145
0x8D31
36160
0x8D40
36161
0x8D41
36176
0x8D50
36177
0x8D51
36192
0x8D60
36193
0x8D61
36208
0x8D70
36209
0x8D71
36224
0x8D80
36225
0x8D81
36240
0x8D90
36241
0x8D91
36272
0x8DB0
36273
0x8DB1
Extended Device Status Type
Meaning
Everything OK
(no IOL event)
Critical condition
Error
Critical condition
Warning
Critical condition
Warning
Critical condition
Warning
Defect/fault
Error
Defect/fault, low
Error
Defect/fault, low
Error
Warning, high
Warning
Warning, high
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Warning
Warning, low
Notification
Warning, low
Notification
Warning, low
Notification
Warning, low
Notification
Defect/fault, high
Error
Defect/fault, high
Error
Critical condiction, high
Warning
Critical condiction, high
Warning
Warning
Warning
IO-Link
Event name
Event Type
Everything OK
General power supply fault
Primary supply voltage over-run
Secondary supply voltage fault
Secondary supply voltage over-run
General malfunction
Measurement range overrun, Ejector 1
Measurement range overrun, Ejector 2
Valve protection active, Ejector 1
Valve protection active, Ejector 2
Evacuation time t1 is greater than limit, Ejector 1
Evacuation time t1 is greater than limit, Ejector 2
Leakage rate is greater than limit, Ejector 1
Leakage rate is greater than limit, Ejector 2
H1 was not reached, Ejector 1
H1 was not reached, Ejector 2
Free-flow vacuum level too high, Ejector 1
Free-flow vacuum level too high, Ejector 2
Vacuum calibration OK, Ejector 1
Vacuum calibration OK, Ejector 2
Vacuum calibration failed, Ejector 1
Vacuum calibration failed, Ejector 2
Data Corruption (EEPROM), Ejector 1
Data Corruption (EEPROM), Ejector 2
Supply pressure fault, Ejector 1
Supply pressure fault, Ejector 2
CM Autoset completed, Ejector 1
CM Autoset completed, Ejector 2
Remark
Device is working optimally
Primary supply voltage (US) too low
Primary supply voltage (US) too high
Secondary supply voltage (UA) too low
Secondary supply voltage (UA) too high
Internal error, Bus fault
Vacuum value > 999 mbar in Ejector 1
Vacuum value > 999 mbar in Ejector 2
Calibration offset 0 set successfully
Sensor value too high or too low, offset not changed
Calibration offset 0 set successfully
Sensor value too high or too low, offset not changed
Internal error, user data corrupted
Internal error, user data corrupted
Input pressure too high or too low
Input pressure too high or too low

Publicité

Table des Matières
loading

Table des Matières