schmalz RECB MATCH Notice D'utilisation page 81

Table des Matières

Publicité

Parameter
Device Settings
Commands
2
0x0002
0
System command
Access Control
90
0x005A
0
Extended device access locks
91
0x005B
0
Pin-Code NFC
Initial Settings
Blow-Off mode Ejector 1
69
0x0045
1
Blow-Off mode Ejector 2
69
0x0045
2
75
0x004B
1
Output filter Ejector 1, switch-off delay for SP2 and SP1
Output filter Ejector 2, switch-off delay for SP2 and SP1
75
0x004B
2
Process Settings Ejector 1
Production Setup - Profile P0 Ejector 1
68
0x0044
0
Air-Saving function
Disable continous sucking
78
0x004E
0
100
0x0064
0
Switchpoint 1 (SP1)
101
0x0065
0
Resetpoint 1 (rP1)
Switchpoint 2 (SP2)
102
0x0066
0
103
0x0067
0
Resetpoint 2 (rP2)
106
0x006A
0
Duration automatic blow
Permissable evacuation time
107
0x006B
0
108
0x006C
0
Permissable leakage rate
119
0x0077
0
Profile name
Production Setup - Profile P1 Ejector 1
180
0x00B4
0
Air-Saving function
Disable continous sucking
181
0x00B5
0
5, 129, 131,
1
byte
165, 167,
wo
168, 169
1
byte
0-255
rw
2
bytes
0-999
ro
1
byte
0-2
rw
1
byte
0-2
rw
2
bytes
0-999
rw
2
bytes
0-999
rw
1
byte
0-2
rw
1
byte
0-1
rw
999 > SP1
2
bytes
rw
> rP1
SP1 > rP1 >
2
bytes
rw
SP2
rP1 > SP2 >
2
bytes
rw
rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
100-9999
rw
2
bytes
0-9999
rw
2
bytes
0-999
rw
0...16
bytes
-
rw
1
byte
0-2
rw
1
byte
0-1
rw
0x81 (dec 129): Reset application
0x83 (dec 131): Back to box (IO-Link-Communciation will be stopped, restart by
power cycle is needed)
-
0xA5 (dec 165): Calibrate all vacuum sensor
0xA7 (dec 167): Reset erasable counters
0xA8 (dec 168): Reset voltages min/max
0xA9 (dec 169): Reset vacuum min/max
Bit 0: NFC write lock
Bit 1: NFC disable
Bit 2: Not used
0
Bit 3: reserved
Bit 4: IO-Link event lock (suppress sending IO-Link events)
Bit 5-7: Not used
0
Pin-Code for NFC write
0 = Externally controlled drop-off
0
1 = Internally controlled drop-off – time-dependent
2 = Externally controlled drop-off – time-dependent
0 = Externally controlled drop-off
0
1 = Internally controlled drop-off – time-dependent
2 = Externally controlled drop-off – time-dependent
10
Unit: 1ms
10
Unit: 1ms
0 = not active (off)
1
1 = active (on)
2 = active with supervision (onS)
0 = off,
0
1 = on
750
Unit: 1mbar
600
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms
2000
no evacuation time warning if set to 0
Unit: 1mbar/s
250
no leakage rate warning if set to 0
***
Name of profile
0 = not active (off)
0
1 = active (on)
2 = active with supervision (onS)
0 = off,
0
1 = on