Resetpoint 1 (rp1)
223
0x00DF
0
224
0x00E0
0
Switchpoint 2 (SP2)
225
0x00E1
0
Resetpoint 2 (rp2)
Duration automatic blow
226
0x00E2
0
227
0x00E3
0
Permissable evacuation time
228
0x00E4
0
Permissable leakage rate
Profile name
239
0x00EF
0
Observation
Monitoring
1
System vacuum live
64
0x0040
2
System vacuum min
3
System vacuum max
1
Primary supply voltage live
66
0x0042
2
Primary supply voltage min
3
Primary supply voltage max
275
0x0113
0
Active profile
Communication Mode
Communication mode
564
0x0234
0
Diagnosis
Device Status
36
0x0024
0
Device status
37
0x0025
0
Detailed device status
130
0x0082
0
Active errors
SP1 > rP1 >
2
bytes
rw
SP2
rP1 > SP2 >
2
bytes
rw
rP2
SP2 > rP2
2
bytes
rw
>= 10
2
bytes
10-9999
rw
2
bytes
0-9999
rw
2
bytes
0-999
rw
0...16
bytes
-
rw
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
1
byte
0-3
ro
1
byte
-
ro
1
byte
-
ro
1
byte
-
ro
2
bytes
-
ro
600
Unit: 1mbar
550
Unit: 1mbar
540
Unit: 1mbar
200
Unit: 1ms
Unit: 1ms
2000
no evacuation time warning if set to 0
Unit: 1ms
250
no leakage rate warning if set to 0
***
Name of profile
Unit: 1mbar
-
Unit: 1mbar
Unit: 1mbar
Unit: 0.1V
-
Unit: 0.1V
Unit: 0.1V
-
Number of active profile
0x00 = SIO mode
-
0x11 = IO-Link revision 1.1
0 = Device is operating properly (= Green)
1 = Maintenance required (= Yellow)
-
2 = Out of Spec (= Orange)
3 = unused
4 = Failure (= Red)
-
Information about currently pending events (Event-List)
Bit 0 = IO-Link startup check: data corruption
Bit 1 = reserved
Bit 2 = Primary voltage too low
Bit 3 = Primary voltage too high
Bit 4 = Auxiliary voltage too low
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = reserved
-
Bit 8 = Short circuit at OUT2
Bit 9 = reserved
Bit 10 = reserved
Bit 11 = Measurement range overrun
Bit 12 = reserved
Bit 13 = reserved
Bit 14 = reserved
Bit 15 = IO-Link communication interruption