26
Operation
3.3 Machine Features
EN
• Double protection to prevent overheating and damage of your machine. The intelligent processor digitally
Thermal Protection
performs temperature control whereas a second protection for the machine will be performed manually.
• If the Igbt block rises above 80 degrees, the red LED lights and the error code will be displayed.
• 100 programs can be stored in the memory. You can record 100 programs between 0-99.
Program Memory
• The changes will be saved. Press the P key to switch between programs.
• Lift TIG function allows TIG to be made without damaging the Tungsten tip while rubbing it.
Lift TIG
• Tolerates voltage fluctuations.
Voltage Protection
• Protection feature against false voltage and oscillating input voltage.
• After the ambient conditions have returned to normal, the machine functions will also be activated.
• Suitable for operation with generators. The kVA operating value should be determined by referring to the technical
Operation With Generators
specifications.
• If the mains voltage is out of tolerance, an error code is given and a warning led is displayed.
Protection
• Machine functions will be re-activated when the phases are corrected.
• You can tell if the fan is running by the fan sound at first power-up.
Smart Fan Control
• If the fan sound is comes when the machine is turned on, this means the fan is running. After a time machine exits
from test mode.
• When the ambient temperature is below 30 degrees, the fan does not start and will be in standby mode.
This prevents dust or metal parts from entering the machine.
• Anti-Stick feature to prevent electrode sticking
Antistick
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
ID 500 TW DC PULSE
www.magmaweld.com