24
Operation
The adjustment knob allows current setting in all welding methods and parameter changes in all
6- Adjustment Button
EN
functions. The setting will be made by turning right and left and the set values will be displayed on the
digital display.
7- Program Memory
• With its 100 program memory feature, it can save your parameter settings. You can recall them as
TIG Mode;
required by your work type. By this means, each time you change the work, you will not have to set
parameters; the production standard will be preserved. Whichever memory (job) number is
selected, all settings will automatically be saved in that number.
• Change the program number for different parameter entries.
• The display above the program button shows which parameter you have changed in the program.
• There are 100 programs available between 0-99.
• You can switch to the other program by pressing the program button once, if you press and hold, you
can switch between the programs quickly.
• (U) When you want to see the welding output voltage, you can see the voltage unit by pressing the
MMA Mode;
button once. You can switch to the ampere unit by re-pressing the button and display the current
value (A) on the digital display.
The set welding current, parameter values and error codes can be monitored visually on the digital
8- Digital Display
display.
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
ID 500 TW DC PULSE
www.magmaweld.com