MCBF
MODELS
Boom L = 3.05 m
Boom L = 4.05 m
Boom L = 3.05 m with joint
Boom L = 4.05 m with joint
The percentages indicate how much the number of cycles should be reduced in relation to the type and number of accessories installed.
The type of intervention and the maintenance frequency are decided by the installer, considering the use, place of installation and number of daily cycles.
If the barrier is not used for long periods, for example in the case of installations in places with seasonal opening, it is advisable to release the balancing
spring and remove the boom.
For information on correct installation and adjustments, refer to the product installation manual.
For information about product and accessory choice, browse the products catalog.
If the barrier with articulated joint is used, check that the movement elements of the joint are in good condition and, if necessary, replace them.
Every 500,000 cycles and in any case every 6 months of operation, the maintenance interventions indicated below are mandatory.
1 - Perform a general and complete check on the the tightness of the nuts and bolts.
2 - Check the 45° boom balance and if necessary tension the balancing spring, adjusting its traction operating on the hooking tie rods.
3 - Lubricate the balancing spring with the spring fully extended.
4 - Lubricate all moving mechanical parts, for example the articulated parts and joints.
5 - Check the proper working state of the indicating and safety devices.
6 - Check that the microswitch connected to the cabinet cover is working correctly.
7 - Check the correct operation of the microswitch connected to the manual release, and of the microswitch connected to the release accessories (optional).
Every 2,500,000 cycles and in any case every 12 months of operation, the maintenance interventions indicated below are mandatory.
1 - Replace the balancing spring.
GPX40MGP
5000000
0%
0%
0%
GPX40MGS
5000000
0%
0%
0%