CAME GARD PX GPX40MGP Manuel D'installation page 63

Masquer les pouces Voir aussi pour GARD PX GPX40MGP:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Total stop
Stops the boom and excludes the automatic closing. Use a control device to resume movement.
Configuration >
Wired safety devices
CX input
It associates a function with the CX input.
Configuration >
Wired safety devices
CY input
It associates a function with the CY input.
Configuration >
Wired safety devices
CZ input
Associate a function with the CZ input.
Configuration >
Wired safety devices
Safety devices test
It activates the check of the correct operation of the photocells connected to the inputs, after each opening and closing command.
Configuration >
Wired safety devices
Total stop
CX input
CY input
CZ input
Safety devices test
Disabled (Default)
Activated
Disabled (Default)
C1 = Reopening while closing (Photocells)
C4 = Obstacle wait (Photocells)
C5 = Immediate closing at the opening travel end
C7 = Reopening while closing (Sensitive safety-edges)
C9 = immediate closing at the travel end during opening with obstacle waiting, during
closing
C10 = Immediate closing during opening with obstacle waiting during closing
C13 = reopening while closing and with immediate stop once the obstruction is
removed, even with boom not in movement
r7 = reopening while closing (Sensitive safety-edges with 8K2 resistor)
Disabled (Default)
C1 = Reopening while closing (Photocells)
C4 = Obstacle wait (Photocells)
C5 = Immediate closing at the opening travel end
C7 = Reopening while closing (sensitive safety-edges)
C9 = immediate closing at the travel end during opening with obstacle waiting, during
closing
C10 = Immediate closing during opening with obstacle waiting during closing
C13 = reopening while closing and with immediate stop once the obstruction is
removed, even with boom not in movement
r7 = reopening while closing (sensitive safety-edges with 8K2 resistor)
Disabled (Default)
C1 = Reopening while closing (Photocells)
C4 = Obstacle wait (Photocells)
C5 = Immediate closing at the opening travel end
C7 = Reopening while closing (sensitive safety-edges)
C9 = immediate closing at the travel end during opening with obstacle waiting, during
closing
C10 = Immediate closing during opening with obstacle waiting during closing
C13 = reopening while closing and with immediate stop once the obstruction is
removed, even with boom not in movement
r7 = reopening while closing (sensitive safety-edges with 8K2 resistor)
Deactivated (Default)
CX
CY
CZ
CX+CY
CX+CZ
CY+CZ
CX+CY+CZ

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gard px gpx40mgsGard px gpx40mgc

Table des Matières