GENERAL PRECAUTIONS FOR INSTALLERS
Important safety instructions.
Follow all of these instructions. Improper installation can cause serious bodily harm.
Before continuing, also read the general precautions for users.
Use this product only for its specifically intended use. Any other use is hazardous.
The manufacturer can not be held liable for any damage caused by improper, unreasonable, and erroneous use.
This manual's product is defined by the Machinery Directive 2006/42/CE as partly-completed machinery.
Partly-completed machinery is an assembly that almost constitutes a machine, but which, alone, cannot ensure a clearly
defined application.
Partly-completed machinery is only destined to be incorporated or assembled to other machinery or other partly-completed
machinery or apparatuses to build machinery that is regulated by the Machinery Directive 2006/42/EC.
The final installation must comply with the Machinery Directive 2006/42/EC and the current European reference standards.
The manufacturer declines any liability for using non-original products; which would result in warranty loss.
All operations indicated in this manual must be carried out exclusively by skilled and qualified personnel and in full
compliance with current regulations.
Laying of cables, installation and testing must follow state-of-the-art procedures as dictated by applicable standards and
laws.
Make sure the mains power supply is disconnected during all installation procedures.
Check that the temperature ranges given and those of the location match.
Make sure that the opening automatic barrier does not constitute a hazard.
Do not install on slopes, that is, on any surfaces that are not perfectly level
If necessary, add suitable reinforcements to the anchoring points. If necessary, add suitable reinforcements to the
anchoring points.
Make sure that the operator, in the installation place, does not get wet by direct jets of water (sprinklers, water cleaners,
etc.).
Make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installation
rules. It should completely cut off the power supply according to category III surcharge conditions.
Demarcate properly the entire site to prevent unauthorized personnel to enter; especially children and minors.
In case of manual handling, have one person for every 20 kg that need hoisting; for non manual handling use proper
hoisting equipment in safe conditions.
During the fixing phases, the operator could be unstable and overturn. Be careful and do not lean on it until it is fully
fastened.
Use suitable protections to prevent any mechanical hazards due to persons loitering within the operating range of the
operator.
The electric cables must pass through special pipes, ducts and cable glands in order to guarantee adequate protection
against mechanical damage.
Make sure that the moving mechanical elements have adequate distance from the wiring made.
The electrical cables must not touch any parts that may overheat during use (such as the motor and the transformer).
All fixed controls must be clearly visible after installation, in position that the guided part is directly visible, but far away
from moving parts. In the case of a maintained action command, this must be installed at a minimum height of 1.5 m from
the ground and must not be accessible to the public.
When the passage width clearance is greater than 3 m, you must use a fixed rest for the boom to support it.
If not already present, apply a permanent tag, that describes how to use the manual release mechanism, close to the
mechanism.
Make sure that the operator has been properly adjusted and that the safety and protection devices, and the manual
release, are working properly.