ALTERNATE OPERATION
Opening of the first barrier, passage of the vehicle, closing of the first barrier, opening of the second barrier, passage of the vehicle and closing of the second
barrier.
Electrical connections
Connect the two electronic boards with a UTP CAT 5 cable.
Fit a RSE card on both control boards, using the RSE_1 connector.
Proceed with the electrical connection of the devices and accessories.
For electrical connections of the devices and accessories, see the ELECTRICAL CONNECTIONS chapter.
The control and safety devices must be connected on both electronic boards.
A
B GND
1
2
3 3P 4
Programming
Choose one of the two operations described below.
On one of the two barriers, select [Alternate] as type of installation, during the guided procedure.
On one of the two barriers, configure the [RSE_1] function in [Alternate].
It activates the function [Automatic cls] on both control boards.
Saving users
For user storage operations, see the [New User] function.
When programming users, do not use the 2-3P OPEN ONLY command.

Operating modes

1 - ONLY OPEN command (2-3) on barrier A
A
B GND
FCA CM1 FCC CM2
5
7
2 CX CY CZ
UTP CAT 5 (max 1000 m)
RSE
A
B GND
1
2
3 3P 4
A
B GND
FCA CM1 FCC CM2
5
7
2 CX CY CZ
RSE