WARNING: To prevent elec tri cal shock, short cir cuit or arc ing, this
prod uct must be in stalled cor rect ly and water ingress must be avoid ed
before and during the in stal la tion.
WARNING: The purchaser should make the manufacturer aware of
any external effects or aggressive substances that the equipment may be
exposed to.
Before installing this product, read the installation instructions completely.
CAUTION: Prolonged or repeated contact with the sealant in the core
sealer may cause skin irritation. Wash hands thoroughly. Overheating or
burning the sealant will produce fumes that may cause polymer fume
fever. Avoid contamination of cigarettes or tobacco. Consult MSDS VEN
0058 for further information.
Rated voltage:
Ambient temperature
** Specific conditions for use apply for ATEX and IECEx.
Maximum pipe temperature:
Heater type
T
BTV
65°C
QTVR
110°C
XTV
121°C
KTV
150°C
HTV
205°C
VPL
See tables below
VPL: Maximum pipe temperature in dependence of heater type, voltage and current
Heater Type
230 Vac
5VPL2-CT
230°C
10VPL2-CT
210°C
15VPL2-CT
180°C
20VPL2-CT
150°C
Heater Type
385 Vac
5VPL4-CT
230°C
10VPL4-CT
215°C
15VPL4-CT
195°C
20VPL4-CT
150°C
For ambient temperatures >+40°C:
Use a power cable with continuous temperature resistance of minimum
+90°C
Use a metallic power cable gland approved for use in hazardous areas
(for example GL-38-M25-METAL).
For voltages >254Vac and BTV, QTVR, XTV, KTV or HTV heating cables:
Use a power cable with continuous temperature resistance of minimum
+90°C
Use a metallic power cable gland approved for use in hazardous areas
(for example GL-38-M25-METAL).
For pipe temperature > 150 °C and XTV, KTV or HTV heating cables, the
maximum operating current shall be reduced to maximum 20 A
6 | nVent.com/RAYCHEM
JBS-100-E(P): 480 Vac**
JBS-100-L-E(P): 277 Vac
JBS-100-E(P): –55°C to +56°C**
JBS-100-L-E(P): –40˚C to +40˚C up to 277 V for BTV, QTVR,
XTV, KTV, HTV and VPL.
continuous
max
254 Vac
277 Vac
225°C
225°C
200°C
195°C
145°C
105°C
Not allowed
400 Vac
480 Vac
230°C
230°C
215°C
205°C
195°C
160°C
150°C
150°C
T
intermittent
max
1000h cumulative
85°C
110°C
250°C
250°C
260°C
20A
180°C - 235°C 150°C - 180°C ≤150°C
180°C - 235°C 150°C - 180°C ≤150°C
≤180°C
≤150°C
20A
180°C - 235°C 150°C - 180°C ≤150°C
180°C - 235°C 150°C - 180°C ≤150°C
≤180°C
≤150°C
T
power off
max
260°C
25A
30A
150°C - 180°C ≤150°C
≤150°C
≤150°C
25A
30A
150°C - 180°C ≤150°C
≤150°C
≤150°C