3.5 ENTRY DELAY
Definition: The time needed to disarm the burglar zones when entering the site before
an alarm is set off. This applies to all burglar zones and ranges from 0 to 5 minutes,
59 seconds. The default is 30 seconds. The entry delay countdown begins when an
alarm is detected in a burglar zone with an entry delay.
Setting:
1. Press the Entry/Exit Delay key
ENTRY DELAY . . . .(1)
EXIT DELAY. . . . . . (2)
2. Type 1 to adjust the entry delay.
ENTRY DELAY
0 MIN, 30 SEC
TO MODIFY. . . . .
TO QUIT. . . . . . .
3. Press Enter
RANGE FROM
(0 .. 5 MIN, 0 .. 59 SEC)
ENTER NEW DELAY
_MIN, _ _ SEC
4. Enter the minutes value and press Enter. Enter the seconds value and press Enter.
The system displays the new setting and returns to the Date/Time display.
Entry / Exit Delay
to adjust the entry delay or Cancel
ENTER
.
6
↵ ↵ ↵ ↵ ↵
(
)
(#)
#
to quit.
Cancel
KP-400.rev.06
31