AGRI-ALERT 9600
KPB 400 KEYPAD
INSTALLATION
M 890-00323
rev. 04
REV. 00

Publicité

loading

Sommaire des Matières pour Agri-Alert KPB 400

  • Page 1 AGRI-ALERT 9600 KPB 400 KEYPAD INSTALLATION M 890-00323 rev. 04 REV. 00...
  • Page 2 MOUNTING THE UNIT Open the KPB-400 by pulling on the latch below the enclosure. Mount the enclosure on the wall using 3/16” diameter screws. Mounting Holes: CONNECTIONS All wires are connected to the main card inside the enclosure. Strip the wires as little as possible (about 1/4”) to avoid electrical shorts when connecting the equipment to the terminals provided.
  • Page 3 Make sure each sensor is connected to the proper COM terminal. False alarms can result if wires are not properly connected. ZONES All zones connected to the KPB 400 are dry contact, burglar or temperature zones (normally closed with or without EOLR/DEOLR; normally open with or without EOLR/ DEOLR).
  • Page 4 Examples of Zone Connections with EOLR 1.5 kΩ 1/2 W 1.5 kΩ 1/2 W N.C. CIRCUIT WITH EOLR N.O. CIRCUIT WITH EOLR Examples of Zone Connections with DEOLR 1.5 kΩ 1/2 W 1.5 kΩ 1/2 W 1.5 kΩ 1/2 W 1.5 kΩ...
  • Page 5 The diagram below shows three examples of load hookups. +SBV AUX PWR +12V KPB 400 +SBV LOAD 3 LOAD 2 LOAD 1 OUTPUT: +SBV - GND: 8-28VDC, 50mA max., 1400mW max.
  • Page 6 WARNING Serial Bus Interface (SBI): The serial bus interface is used to con- nect the different Agri-Alert devices together. Four wires are needed for this purpose. Use a shielded twisted pair cable (see the appendix for maximum length and wire gauge recommendations).
  • Page 7 The figure below shows an example of how the end of line jumpers are configured for an Agri-Alert network installation. TP 800 KPB 400 AA9600 KP 400 End of line = YES End of line = NO End of line = NO End of line = YES KPB-400.rev.04...
  • Page 8 KEYPAD ID NUMBER The KPB-400 barn keypad must have a unique id number to connect with the Agri-Alert net- work. After making the connections and turning the power on, follow the procedure below to assign an id number to the keypad: System 1.
  • Page 9 KPB-400 devices to the AA-9600. Note that each device has an auxiliary load. For example, if you connect 2 TP-800 devices and 2 KPB-400 devices to the Agri-Alert, the maximum length for a 22 AWG wire is 1468 feet where each TP-800 and KPB- 400 has an auxiliary load of 20mA.