8.2 Calculation of accuracy (g) at a working distance other than 5 m
g = (3 mm x working distance (m))/5 m.
In this case, the horizontal distance between d1 and d2 must not exceed
the value (g) at the defined working distance (m).

9. Care and maintenance

9.1 Cleaning and drying

Blow dust off the glass.
Do not touch the glass with your fingers.
Use only a clean, soft cloth for cleaning. If necessary, moisten the cloth
slightly with pure alcohol or a little water.
-NOTE-
Do not use any other liquids as these may damage the plastic compo-
nents.
Observe the temperature limits when storing your equipment. This is par-
ticularly important in summer if the equipment is kept inside a motor vehi-
cle (–20 °C to + 63 °C/–4 °F to 145 °F).
9.2 Storage
Remove the tool from its case if it has become wet. The tool, its carrying
case and accessories should be cleaned and dried (at maximum 40 °C/104
°F). Repack the equipment only once it is completely dry.
Check the accuracy of the equipment before it is used after a long period
of storage or transportation. Remove the batteries if the tool is not used
over a long period. Leaking batteries may damage the tool.
9.3 Transportation
Use the Hilti shipping carton, Hilti toolbox or packaging of equivalent qual-