Fault
en
The tool can't
be switched
on.
Individual
laser beams
don't function.
The tool can
be switched
on but no
laser beam is
visible.
Automatic
leveling
doesn't
function.
Printed: 07.07.2013 | Doc-Nr: PUB / 5070095 / 000 / 00
Possible causes
Batteries are exhausted.
Batteries are inserted the
wrong way round
(incorrect polarity).
Battery compartment is
not closed.
Tool or selector button is
defective.
The laser source or laser
control is defective.
The laser source or laser
control is defective.
Temperature too high or
too low.
The surface on which
the tool is set up is
excessively inclined.
Extraneous light is too
bright.
The tilt sensor is
defective.
Remedy
Replace the batteries.
Insert the batteries
correctly.
Close the battery
compartment.
Bring the tool to a Hilti
repair center.
Bring the tool to a Hilti
repair center.
Bring the tool to a Hilti
repair center.
Allow the tool to cool down
or, respectively, warm up.
Set up the tool in a level
position.
Reduce extraneous light.
Bring the tool to a Hilti
repair center.