6.4 Service menu (password required)
The Service menu is used to modify the brake resistance thresholds, the overcurrent threshold
and the anti-wind function when the encoder intervenes.
To access the Service menu:
-
STOP the door
-
Set DIP5 to ON
-
Enter the PW: button sequence OPEN- OPEN- CLOSE- PARTIAL OPENING
Remove cables from PIN 3, 4, 20 during programming
STEP 1
level options
st
1
MIN BRAKING VOLT.
Default 340Vdc
2
MAX BRAKING VOLT.
Default 380Vdc
3
OVERCURRENT LIMIT
Default 10A
4
RAMP SLOPE DURING
OPENING
5
BATTERY LEVEL
6
ALARM LIST
ONCE PROGRAMMING HAS ENDED, SET DIP5 TO OFF

6.5 Display messages

MESSAGE
Ditec
Opening of VBUS IBUS
Door open - automatic closing time
Closing of VBUS IBUS
Input 40 closed; input 8 open
input 40 open; input 8 closed
Thermal or release micro open
Opening safety device activated
Door stopped

6.6 Interlock

Notes
Threshold for partial intervention of braking resistance
Threshold for total intervention of braking resistance
If the current on the BUS exceeds the set threshold, the door opens at half the
speed to reduce absorption.
Changes the slope of the deceleration ramp when opening. Default 15.
(If the value is increased, the ramp distance is reduced).
Visualizes the encoder battery charge level from 0% to 100%
The last 50 alarms are displayed: Overcurrent; bus voltage exceeds limit,
Intervention of brake resistance, inverter overtemperature, faulty motor driver
(encoder). To exit, press partial opening
SITUATION
door closed waiting for command
door opening
Door open
door closing
intervention of photocell
intervention of encoder (SLE)
Intervention of safety micro on manual
opening device / intervention of motor
thermal switch.
photocell engaged when door is
closed and door does not open
stop command activated
DOOR 1
INPUT
+24V
1 IN NC C NO
M4
INPUT
Logical
+24V
operation
1 IN NC C NO
- 45 -
ON
1 2 3 4 5 6 7 8
NOTES
When door is moving
When door is moving
Message that only appears if the
"opening safety" function is set to YES
on the advanced menu (step 7).
DOOR 2
M4
EN
0DT848 01-12-2021

Publicité

Table des Matières
loading

Table des Matières