Measurement inac-
Max. permissible standard deviation according
curacy
to clinical testing: systolic 8 mmHg /
diastolic 8 mmHg
Memory
2 x 60 memory spaces
Dimensions
L 139 mm x W 96 mm x H 59 mm
Weight
Approx. 264 g (without batteries)
Cuff size
22 to 36 cm
Permissible operating
+5 °C to +40 °C, 15%-93% relative air humidity
conditions
(non-condensing)
Permissible storage
-25 °C to +70 °C, ≤ 93 % relative air humidity,
and transport con-
700 –1060 hPa ambient pressure
ditions
Power supply
4 x 1,5 V
Battery life
For approx. 250 measurements, depending on
the blood pressure level and/or pump pressure
Classification
Internal supply, IPX0, no AP or APG, continuous
operation, type BF
applied part
The serial number is located on the device or in the battery compartment.
Technical information is subject to change without notification to allow
for updates.
• This unit is in line with European Standard EN 60601-1-2 (in accord-
ance with CISPR 11, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11) and is
subject to particular precautions with regard to electromagnetic com-
AA batteries
patibility (EMC). Please note that portable and mobile HF communica-
tion systems may interfere with this unit.
• This device is in line with the EU Medical Devices Directive 93/42/
EEC, the „Medizinproduktegesetz" (German Medical Devices Act) and
the standards EN 1060-1 (non-invasive sphygmomanometers, Part 1:
General requirements), EN 1060-3 (non-invasive sphygmomanometers,
Part 3: Supplementary requirements for electro-mechanical blood pres-
sure measuring systems) and IEC 80601-2-30 (Medical electrical equip-
ment – Part 2 – 30: Particular requirements for the safety and essential
performance of automated non-invasive blood pressure monitors).
• The accuracy of this blood pressure monitor has been carefully
checked and developed with regard to a long useful life. If using the
device for commercial medical purposes, it must be regularly tested for
accuracy by appropriate means. Precise instructions for checking ac-
curacy may be requested from the service address.

11. Mains part

Model no.
LXCP12-006060BEH
Input
100 – 240 V, 50 – 60 Hz, 0.5 A max
Output
6 V DC, 600 mA, only in connection with beurer
blood pressure monitor.
Supplier
Shenzhen Iongxc power supply co., ltd
Protection
This device is double insulated and protected
against short circuit and overload by a primary
thermal fuse.
Make sure to take the batteries out of the com-
partment before using the mains adapter.