Determining the end run points
Position the end run fins on the rack and secure them using the 3 mm hex key. Their position limits the gate run.
N.B. ensure that the gate does not strike against the mechanical stop during opening or closing.
ELECTRICAL CONNECTIONS
⚠ Caution! Before intervening on the control panel, disconnect mains power.
Control board power supply: 230/400 VAC three-phase, with frequency of 50-60 Hz.
Control device power supply: 24 VAC.
⚠ The total power of the accessories should not exceed 40 W.
The functions must be set using the dip switches and the adjustments using the trimmers.
All the connections are protected by quick fuses.
FUSE TABLE
Line fuses
Panel fuse
Accessory fuse
Description of the components
1.
Dip switch
2.
Panel fuse
3.
Accessory fuse
4.
Line fuses
5.
Connector for AF card
6.
Power indicator LED
7.
Programming indicator LED
8.
Terminal block for control and
safety devices
9.
Transformer terminal block
10. Radio code memorisation
buttons
11. ACT trimmer: adjusting the
automatic closing time
12. PART.OP. trimmer: adjusting
partial opening
Left-hand end run fi n
8 A-F
630 mA-F
2 A-F
9
4
Right-hand end run fi n
6
3
2
11
12
7
1
5
10