Stop button (N.C. contact) Stops the gate with the exclusion of
automatic closing. To resume movement, press the control button
or other control device.
N.B. if not used, set dip switch 10 to ON.
OPEN ONLY function from the control device (N.O. contact)
PARTIAL OPENING function from the control device (N.O. contact)
CLOSE ONLY function from the control device (N.O. contact)
OPEN-STOP-CLOSE-STOP (sequential) function / OPEN-CLOSE-
REVERSE (step-by-step) from the control device (N.O. contact)
See dip switch 2 and 3 function selection.
Indicator and lighting devices
Flashing light (Contact rated for:
230 V AC - 25 W max.).
Flashes during gate opening and
closing.
Gate open indicator light (contact capacity:
24 V - 3 W max.)
Indicates that the gate is open.
Cycle/courtesy lamp (Contact capacity: 230 V - 60 W max.).
With dip switch 16 set to OFF and dip switch 17 set to ON = Cycle lamp.
Lights the area of operation. It remains on from the start of gate opening
to complete closing (including the automatic closing time).
With dip switch 16 set to ON and dip switch 17 set to OFF = Courtesy
lamp.
Lights the area of operation; stays on for a set time of 330 seconds after
an opening command.
Gate closed indicator light (contact
capacity: 24 V - 3 W max.)
Indicates that the gate is closed.