Confi gure travel M2
Modify certain parameters previously described for motor M2 only (where diff erent from M1).
The function appears only with M1+M2 selected in [Function Number of Motors].
Confi guration>
Gate travel settings>
Confi gure travel M2
Total stop
Activate or deactivate input 2-1. If it is activated, the input is used as a normally closed contact.
With the input open, this function excludes all commands, including any automatic closing.
Confi guration>
Wired safety devices
CX input, CY input, CZ input, CK input
Associate a function with the input CX or CY or CZ or CK
Confi guration>
Wired safety devices
Opening speed
Closing speed
Opening approach space
Closing approach space
Opening slowdown point
Closing slowdown point
Opening slowdown speed
Closing slowdown speed
Total stop
CX input
CY input
CZ input
CK input
See the specifi c parameters for each function.
Deactivated (Default)
On
Deactivated (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive edges)
C8 = Reclose while opening (sensitive edges)
C13 = Reopen while closing, with immediate stop once
the obstruction has been removed, even if the gate is not
in motion
r7 = Reopen while closing (sensitive edges with 8K2
resistor)
r8 = Reclose while opening (sensitive edges with 8K2
resistor)
r7 (two sensitive edges) = Reopen while closing (pair of
sensitive edges with 8K2 resistor)
r8 (two sensitive edges) = Reopen while closing (pair of
sensitive edges with 8K2 resistor)