The pressure of the nozzle line is adjusted with the adjusting screw of the TV valve. The oil in excess to nozzle require-
ment is dumped to the return. Two pipe system : oil in excess is returned to tank. One pipe system : oil in excess is
returned to pump suction.
VALVE
IDENTIFICATION
(Not all model combinations are available
Consult your Suntec representative)
TV :
Pressure regulating valve
Pressure range :
10 : 2 - 10 bars
40 : 7 - 40 bars
TV
40
01
Regulation type :
01 : by screw
02 : by piston,
for modulating purpose
Revision number
General
Connection threads
Inlet
To nozzle
Return
Weight
VALVE SUNTEC TV TECHNICAL DATA
Oil under suction
1
Oil under pressure
By-passed oil
returned to tank,
or to suction
To nozzle
Cylindrical according to ISO 228/1
G 3/4"
G 3/4"
G 3/4"
3 kg
420010401800 Multicalor 700.1 - 1200.1 PR/PR
Oil under pressure
Intake
Return
By-passed oil
To nozzle
Return
TV
valve
T pump
Hydraulic data
Pressure ranges
10 : 2 - 10 bars
(delivery pressure setting : 7 bars)
40 : 7 - 40 bars
(delivery pressure setting : 20 bars)
Operating viscosity 4 - 450 cSt
Oil temperature
0 - 150°C max. in the valve.
25
EN
Pressure
adjustment
To tank
R
e
u t
n r
o t
suction
Intake
from Tank