Framing
The 563SCB Senator Front comes
supplied with a framing plate for zero
clearance applications. The framing
plate is painted black and may be left
exposed beyond the perimeter of the
cast iron front or may be covered with
non-combustible material if desirable.
• A non-combustible hearth is not
necessary in front of this appliance.
• The appliance is approved to install
directly on wood sub-fl ooring.
• Any framing construction must be
clear of stand-offs.
• Be aware that the area of 7½" x 26¼"
(19 cm x 67 cm) immediately above
the framing plate must be constructed
with non-combustible materials as
shown in fi gures.
4
Raised plinth
not shown
Framing plate exposed
Raised plinth
not shown
Framing plate covered
Tab Detail
Framing Plate Protudes
by desired wall finish
thickness
non-combustible finish
& backing required
Mount Brackets to Heater
Install Framing Plate
flush with framing or
butt drywall to plate
and run finish over plate
Bend Tabs out
for desired wall
finish thickness