H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Type of Error
No GPS Signal
Poor GPS Signal
c. Welding Process
Temperature low
Temperature high
Low Voltage
High Voltage
Error Changeover
Error Drag Pressure
Error Build-up Pressure
Error Heat Soak
Pressure
Error Joining Pressure
Overheated
Cooling Stopped
Temperature Too Hot
Error Plate Temperature Heating element temperature is out of tolerance; impos-
Emergency Stop
4.6
Using ViewWeld to Manage Logged Welding Reports, Print
Tags, and Assign Geo-data
The View Weld feature offers viewing an abstracted version
of the welding report recorded during the last welding pro-
Version October 2022
There is no reliable signal from the relevant satellites to
the GPS antenna of the module.
The signal strength is so weak that no precise position can
be recorded. Repeating the recording is recommended.
The heating element temperature will be increased
automatically.
The heating element temperature will be reduced
automatically.
The input voltage to the hydraulic and control unit is
< 185 V; the welding process is likely flawed, and repeating
it is recommended.
The input voltage to the hydraulic and control unit is
> 280 V; the welding process is likely flawed, and repeating
it is recommended.
It took too long to retract the heating element and bring
the pipes to joining; welding will have to be repeated.
Impossible to determine the drag pressure; maybe pipes
will have to be clamped once again.
The computed maximum pressure for the welding, which
will be applied during bead build-up and jointing, is too
high; impossible to start welding; maybe pipes will have to
be clamped once again.
The heat-soaking pressure is too high and could not be
re-adjusted.
The joining pressure is too high or too low and , could not
be re-adjusted.
The temperature of the hydraulic unit is too high. The next
welding may result in overheating of the unit, which is
why the welding operation is possible only after a period
of letting the hydraulic unit cool.
Operator has stopped the cooling time by pressing the
STOP/REST key.
The temperature of the hydraulic and control unit is
> 100 °C and it has switches itself off for safety reasons; the
welding process must be repeated.
sible to re-adjust the temperature; if no heating element
failure can be found, maybe the ambient temperature was
too low.
The welder has switched the machine off using the
Emergency Stop switch. If this was done because of a
malfunction of the machine, it must not be turned on
again, unless it is beyond doubt that it works properly.
HÜRNER CNC ECO 250 2.0 User's Manual
Description
29