LERBAKKEN 10, 8410 RØNDE DENMARK
Zone dangereuse
Zone 0,1, 2, 20, 21, 22
T
9106B1A, 9106B1B
Entrée S.I. : Source de courant de boucle
1 à 2
Voie 1 (borne 44)
Voie 2 (borne 52)
U
:
28 V
o
I
:
93 mA
o
P
:
0,65 W
o
IIC
IIB
C
0,08 F
0,600 F 2,15 F
o.
L
3 mH
12 mH
o.
Revision date:
2011-11-20
Zone non dangereuse
ou Zone 2
-20 ≤Ta ≤ +60ºC
44
43
+
CH1
42
41
54
53
CH2
-
52
51
91 92 93 94 95
IIA
I
3,76 F
25 mH
30 mH
Version Revision
V3 R0 – FR01
9106 - Version de produit 9106-002
(bornes 11,12,13,14)
(bornes 31,32,33,34)
(bornes 91,92,93,94,95)
U
: 253 V, max. 400 Hz
m
4501
34
33
32
31
14
13
12
11
9106
Power
Rail
9106B2A, 9106B2B
Entrée S.I. : Source de courant de boucle
1 à 2
Voie 1 (borne 44)
Voie 2 (borne 52)
U
:
25,6 V
o
I
:
100 mA
o
P
:
0,64 W
o
IIC
IIB
C
0,800 F 2,75 F 4,65 µF
0,10 F
o.
L
2 mH
9 mH
o.
Prepared by:
PB
9106QA01
IIA
I
15 mH
25 mH
Page:
4/5
31