PR electronics 5333 Manuel De Produit

Masquer les pouces Voir aussi pour 5333:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Manuel de produit
5333
Transmetteur 2-fils
universel (Pt100)
T E M P É R AT U R E
|
I N T E R FA C E S S . I .
No. 5333V117- FR
A par tir du n
de série : 2118 0 9511
o
|
I N T E R FA C E S D E C O M M U N I C AT I O N
PERFORMANCE
|
U N I V E R S E L
|
I S O L AT I O N
MADE
SMARTER
|
A F F I C H E U R S

Publicité

Table des Matières
loading

Sommaire des Matières pour PR electronics 5333

  • Page 1 PERFORMANCE MADE SMARTER Manuel de produit 5333 Transmetteur 2-fils universel (Pt100) T E M P É R AT U R E I N T E R FA C E S S . I . I N T E R FA C E S D E C O M M U N I C AT I O N...
  • Page 2: Performants Individuellement, Inégalés Lorsqu'ils Sont Associés

    6 gammes de produits pour répondre à tous vos besoins Performants individuellement, inégalés lorsqu’ils sont associés Grâce à nos technologies innovantes et brevetées, nous améliorons et simplifions le conditionnement des signaux. Nos produits se déclinent en six gammes composées de nombreux modules analogiques et numériques couvrant plus d’un millier d’applications d’automation industrielle.
  • Page 3: Table Des Matières

    Transmetteur 2-fils universel (Pt100) 5333 Sommaire Application ................... . .
  • Page 4: Application

    à 3 fils. Installation 2-fils en salle de contrôle Montage / installation Résistance en 4...20 mA • Pour tête de sonde DIN B. En zone non-dangereuse le 5333 peut être monté sur rail DIN avec un support spécifique. 5333V117-FR...
  • Page 5: Références De Commande

    Références de commande Type Version 5333 Zone 2 / Div. 2 Zone 0, 1, 2, 21, 22, M1 / DIV. 1, DIV. 2 Accessoires 5909 = Interface USB Loop Link et logiciel PReset Spécifications techniques Conditions environnementales : Température de fonctionnement ......-40°C à +85°C Calibration temperature.
  • Page 6 Spécifications électriques, entrée : Entrée RTD et entrée résistance linéaire : Type Valeur Valeur Plage min. max. min. Standard Pt100...Pt1000 -200°C +850°C 25°C IEC 60751 Ni100...Ni1000 -60°C +250°C 25°C DIN 43760 Rés. linéaire 0 Ω 10000 Ω 30 Ω ----- Décalage max.
  • Page 7: Connexions

    Schéma de principe Alimentation + 8...35 Vcc 4 m A Entrée + C PU Comm. R. Lin. A / D M UX Comp. + Entrée - D / A 0...16 E E PRO M Alimentation - 4...20 mA 5333 5333V117-FR...
  • Page 8: Programmation

    Programmation • Loop Link est un kit de programmation permettant de programmer le 5333. • Pour le raccordement du Loop Link, veuillez vous reporter au schéma ci-dessous et à l’aide en ligne du logiciel PReset. • Loop Link ne doit pas être utilisé pour communication avec des modules installés en zone dangereuse.
  • Page 9: Schéma D'installation Atex 5333Qa02-V3R0

    Schéma d’installation ATEX 5333QA02-V3R0 Pour une installation sûre du 5333A vous devez observer ce qui suit. Le module sera seulement installé par un personnel qualifié qui est informé des lois, des directives et des normes nationales et internationales qui s'appliquent à...
  • Page 10 Notes d'installation Si l’enceinte se compose de matériaux plastiques non métalliques, les décharges électrostatiques sur le boîtier du transmetteur doivent être évitées. Si le transmetteur est installé dans une atmosphère explosive exigeant l'utilisation du niveau de protection de l'équipement Gc, et il est appliqué en type de protection Ex ic, le transmetteur doit être installé...
  • Page 11: Schéma D'installation Atex 5333Qa01-V3R0

    Schéma d’installation ATEX 5333QA01-V3R0 Pour une installation sûre du 5333D vous devez observer ce qui suit. Le module sera seulement installé par un personnel qualifié qui est informé des lois, des directives et des normes nationales et internationales qui s'appliquent à ce secteur. L'année de la fabrication est indiquée dans les deux premiers chiffres dans le numéro de série.
  • Page 12 Classe de Plage de température ambiante température Pi: 0,84 W Pi: 0,75 W -40°C à +47°C -40°C à +50°C -40°C à +62°C -40°C à +65°C -40°C à +85°C -40°C à +85°C Notes d'installation Si l’enceinte se compose de matériaux plastiques non métalliques, les décharges électrostatiques sur le boîtier du transmetteur doivent être évitées.
  • Page 13 IECEx-installation drawing 5333QI02-V3R0 For safe installation of 5333A the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number.
  • Page 14 Installation notes If the enclosure is made of non-metallic plastic materials, electrostatic charges on the transmitter enclosure shall be avoided. If the transmitter is installed in an explosive atmosphere requiring the use of equipment protection level Gc and applied in type of protection Ex ic, the transmitter shall be mounted in an enclosure that provides a degree of protection of at least IP20 according to IEC 60529, and that is suitable for the application and correctly installed.
  • Page 15 IECEx-installation drawing 5333QI01-V3R0 For safe installation of 5333D the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number.
  • Page 16: Installation Notes

    Temperature Ambient temperature range Class Pi: 0.84 W Pi: 0.75 W -40°C to +47°C -40°C to +50°C -40°C to +62°C -40°C to +65°C -40°C to +85°C -40°C to +85°C Installation notes If the enclosure is made of non-metallic plastic materials, electrostatic charges on the transmitter enclosure shall be avoided.
  • Page 17: Fm Installation Drawing - 5333D

    5300Q502 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM FM Installation Drawing Model 5331D, 5332D, 5333D and 5343B Non Hazardous Location Hazardous (Classified) Location Class I,Division1, Groups, A,B,C,D T4..T6 Associated Apparatus Class I, Zone 0, AEx ia IIC T4..T6 or Barrier with Ambient temperature limits entity Parameters: T4: ‐40 to + 85 deg. Celcius T6: ‐40 to + 60 deg. Celcius UM <...
  • Page 18 5300Q502 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM The entity concept The Transmitter must be installed according to National Electrical Code (ANSI-NFPA 70) and shall be installed with the enclosure, mounting, and spacing segregation requirement of the ultimate application. Equipment that is FM-approved for intrinsic safety may be connected to barriers based on the ENTITY CONCEPT.
  • Page 19 CSA Installation drawing 5333QC02 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM For safe installation of the 5333A the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area.
  • Page 20 CSA Installation drawing 533XQC03 – V4R0 Hazardous area Non Hazardous Area T4: -40 ≤ Ta ≤ 85ºC T6: -40 ≤ Ta ≤ 60ºC Module 5331D, 5333D Terminal: 3,4,5,6 Only passive, or non-energy storing devices such as RTD’s and Thermocouples may be connected Barrier Module 5335D, 5336D and 5337D...
  • Page 21 5333QB02 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Desenho de Instalação INMETRO Para instalação segura do 5333A ou 5343A o seguinte deve ser observado. O modo deve apenas ser instalado por pessoas qualificadas que são familiarizadas com as leis nacionais e internacionais, diretrizes e padrões que se aplicam a esta área.
  • Page 22 5333QB01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Desenho de Instalação INMETRO Para instalação segura do 5333D ou 5343B o seguinte deve ser observado. O modelo deve apenas ser instalado por pessoas qualificadas que são familiarizadas com as leis nacionais e internacionais, diretrizes e padrões que se aplicam a esta área.
  • Page 23 5333QB01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Notas de Instalação. Em uma atmosfera de gás potencialmente explosiva, o transmissor deve ser montado em um invólucro a fim de garantir no mínimo um grau de proteção IP20 de acordo com ABNT NBR IEC60529.
  • Page 24: Historique Du Document

    Historique du document La liste ci-dessous vous indique les notes de révisions de ce document. Rev. ID Date Notes 1345 Homologations IECEx et INMETRO ajoutées. 1514 Homologation PESO/CCOE ajoutée. Homologation GOST remplacée par homologation EAC. 1707 Schémas d’installation FM mis à jour. Schémas d’installation INMETRO mis à...
  • Page 25 Nous sommes à vos côtés, aux quatre coins de la planète Bénéficiez d’une assistance où que vous soyez Tous nos produits sont couverts par un service une portée mondiale. Cela signifie que nous sommes d’expertise et une garantie de 5 ans. Pour chaque produit toujours à...
  • Page 26: Bénéficiez Dès Aujourd'hui

    Bénéficiez dès aujourd’hui DE PERFORMANCES À VOTRE SERVICE Leader sur le marché des technologies, PR electronics s’est donné pour mission de rendre les process industriels plus sûrs, plus fiables et plus efficaces. Notre objectif est resté le même depuis notre création en 1974 : améliorer sans cesse nos compétences centrales et proposer des technologies haute précision toujours plus innovantes et garantissant une...

Ce manuel est également adapté pour:

5333a5333d

Table des Matières