LAVAZZA EP 2302 Manuel Pour L'utilisateur page 20

Masquer les pouces Voir aussi pour EP 2302:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

GB
In the case of a prepaid unit, follow the instructions of the machine used for selecting the
sum of money required.
The machine can be used at two different prices or at a fixed price.
C C o o n n d d i i t t i i o o n n f f o o r r t t h h e e t t w w o o p p r r i i c c e e s s
When the amount of money inserted in the totalizer coincides with the first price chosen,
only the green button on the left will light up. Only the small dose works (if you push the
button of the medium dose or large dose, the machine will not work).
When the amount of money inserted coincides with the second price chosen, all the
three dosage buttons will light up. The selection will take place as it has been already
explained before.
C C o o n n d d i i t t i i o o n n f f o o r r a a n n o o n n l l y y p p r r i i c c e e
When the money is inserted in the coin box, all the three dosages will work.
The selection and the consequent way of operating will follow the above mentioned
description.
F F a a u u l l t t c c o o n n d d i i t t i i o o n n s s
Whenever there is an interruption to electric power supply, the machine, when the power
supply is back, will return to the zero point; for the delivery you have to insert again the
pod or a token and select the dose.
The flashing LED "Water level" signals that the water is missing in the tank; the dose
already selected will be delivered but the machine will not delivery any more drinks and
the coin box will refuse any token till the water tank is full again and the machine will
Only for machines with provision for connection to the water mains:
start operating normally. Any eventual credit is not lost.
it is not necessary to access the tank since, when the reserve is reached, the machine
automatically cuts in to top itself up with water from the mains. During the topping-up
period the reserve indicator blinks, the dosing LEDs go out, a possible totalizer unit refuses
money and the appliance cannot operate. Any possible credit available is not lost.
If there was a credit in progress, the dosing LEDs light up again to allow selection when
the optimal operating conditions are restored.
Each new pod automatically expels the previous pod
which falls into the drawer (Figure 10).
The tray should be emptied once it is full of pods.
Fig. 10
18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ep 2303