4 Steam Duct - Before proceeding with the installation of the steam duct, itis necessary to determine the position of
the diffuser.
The diffusers must be installed in the lower part of an inner wall of the Turkish bath compartment, at a 25 cm
distance from the floor.
The steam pipes must not exceed a total length of 5 m.
Do not install a gate in the steam duct. The steam flow must be free and the duct must be free from siphons
taking care to ensure the pipe has a natural slope from the generator to the Turkish bath compartment to allow for
discharging the condensate.
- Use copper or brass pipes with maximum length 5m.
- Insulate the steam ducts properly.
- Do not place the steam diffuser close to the seating stations; steam can cause burns.
- Seal the pipe unions with suitable material so as to prevent any leakage of steam.
- Do not block the steam duct or outlet holes.
5 Water supply - It is advisable to install a cut-off cock (not supplied) to be able to close the water during the
maintenance operations of the appliance, Power the generator only with cold water (Max 25°C). If solid particles are
present in the water, we recommend installing a filter
If the feed water of the generator is "hard" or "averagely hard" (>30 °f) we recommend installing a water
softener to safeguard the steam boiler or carry out more frequent decalcification. The Generator boiler is
subject premature deterioration without decalcifier.
The pressure of the incoming water must not exceed 8 bar (800 kPa) max. For optimal use, the water pressure
should be between 1.5 ÷ 2 bar (150 ÷ 200 kPa) max; Fix the pipe to the wall with the threaded terminal ½" F
6 Water discharge - (Ø 32)
In addition to resisting high temperatures (max 100°C), the drain line must ensure correct outflow of water;
therefore a downward slope of about 5% is recommended. Connect the exhaust valve directly to the drain line
without interposing closing gates, avoid siphoning or narrowing of the diameter. The minimum diameter of the pipe
is ø 32. Prepare the pipe with ø 32 already siphoned female end;
The water is boiled with transformation into steam inside the generator, without the addition of any type of substance.
Thus, the drainage water contains the same substances dissolved in the feed water but in greater quantity, depending
on the concentration in the feed water and the set drainage cycles, and can reach a temperature of 100°C. Use high
temperature resistant pipes for the discharge line.
Since it is not toxic, it can be drained in the drainage system for white waters.