Sew Eurodrive MOVIFIT compact MBF07B-503-K2-A1-0-00 Notice D'exploitation page 29

Table des Matières

Publicité

Short Circuit Current Ratings
Suitable for use on a circuit capable of delivering not more than 10,000 rms symmetri-
cal amperes when protected as follows:
All models are rated 10 kA when protected as follows:
The max. voltage is limited to 500 V.
Suitable for motor group installation on a circuit capable of delivering not more than
10,000 rms symmetrical amperes when protected as follows:
All models are rated 10 kA for group installation when protected as follows:
The max. voltage is limited to 500 V.
Branch Circuit Protection
Integral solid state short circuit protection does not provide branch circuit protection.
Branch circuit protection must be provided in accordance with the National Electrical
Code and any additional local codes.
For maximum branch circuit protection see table below.
Model
MOVIFIT
compact
Motor Overload Protection
MOVIFIT
thermal memory retention upon shutdown or power loss.
The trip current is adjusted to 140 % of the rated motor current.
Ambient Temperature
MOVIFIT
de-rated output current. To determine the output current rating at temperatures above
40 °C, the output current should be de-rated by 3 % per K between 40 °C and 60 °C.
Wiring Diagram
For wiring diagrams, refer to chapter "Electrical Installation".
®
MOVIFIT
compact MBS (starter)
The UL and cUL approval for the MOVIFIT
500 V minimum, 20 A maximum, non-semiconductor fuses or
500  V minimum inverse time circuit breakers with an interrupting rating not less
than 10,000 rms symmetrical amperes.
Combination Motor Controller Model MS132-2.5, manufactured by ABB Rated
500 V, 2.5 A
500 V minimum, 20 A maximum, non-semiconductor fuses or
500 V minimum, 20 A maximum inverse time circuit breakers with an interrupting
rating not less than 10,000 rms symmetrical amperes.
Non-semiconductor
fuses
®
20 A maximum
500 V minimum
®
compact is provided with load and speed-sensitive overload protection and
®
compact is suitable for an ambient temperature of 40 °C, max. 60 °C with
SCCR: 10 kA/500 V when protected by
Inverse time
circuit breakers
20 A maximum
500 V minimum
®
compact MBS (starter) is in preparation.
Notice d'exploitation – MOVIFIT
Installation électrique
Consignes d'installation
Combination
Motor Controllers
ABB Model MS132-2.5,
rated 500 V, 2.5 A
®
compact
5
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Movifit compact mbf07b-503-b2-a1-0-00Movifit compact mbf07b-503-k2-a2-0-00Movifit compact mbf07b-503-b2-a2-0-00Movifit compact mbf11b-503-k2-a1-0-00Movifit compact mbf11b-503-b2-a1-0-00Movifit compact mbf11b-503-k2-a2-0-00 ... Afficher tout

Table des Matières