Vérification Des Ventilateurs (Lom -F) - Sun Microsystems Sun Fire V1280 Guide D'administration

Masquer les pouces Voir aussi pour Sun Fire V1280:
Table des Matières

Publicité

Si vous ne spécifiez aucun niveau, les rapports qui s'affichent concernent les
événements de niveau 1, 2 et 3.
L'
EXEMPLE DE CODE 5-3
EXEMPLE DE CODE 5-3
# lom -e 11
LOMlite Event Log:
Fri Jul 19 15:16:00 commando-sc lom: Boot: ScApp 5.13.0007, RTOS
23
Fri Jul 19 15:16:06 commando-sc lom: Caching ID information
Fri Jul 19 15:16:08 commando-sc lom: Clock Source: 75MHz
Fri Jul 19 15:16:10 commando-sc lom: /N0/PS0: Status is OK
Fri Jul 19 15:16:11 commando-sc lom: /N0/PS1: Status is OK
Fri Jul 19 15:16:11 commando-sc lom: Chassis is in single
partition mode.
Fri Jul 19 15:27:29 commando-sc lom: Locator OFF
Fri Jul 19 15:27:46 commando-sc lom: Alarm 1 ON
Fri Jul 19 15:27:52 commando-sc lom: Alarm 2 ON
Fri Jul 19 15:28:03 commando-sc lom: Alarm 1 OFF
Fri Jul 19 15:28:08 commando-sc lom: Alarm 2 OFF
Vérification des ventilateurs (lom -f)
Pour vérifier l'état des ventilateurs, tapez :
EXEMPLE DE CODE 5-4
# lom -f
Fans:
1 OK speed self-regulating
2 OK speed self-regulating
3 OK speed self-regulating
4 OK speed self-regulating
5 OK speed self-regulating
6 OK speed self-regulating
7 OK speed self-regulating
8 OK speed self-regulating
9 OK speed 100 %
10 OK speed 100 %
#
Chapitre 5 Utilisation des commandes LOM (Lights Out Management) et du System Controller de Solaris
représente un exemple de journal des événements.
Exemple de journal des événements LOM (par ordre d'ancienneté
des événements)
Exemple de sortie issue de la commande lom -f
49