9. The tool menu - functions
When you are in the tool menu (see section 8), you can use the tools described below. Step between the various tool
fields by pressing the up or down arrow symbols. You can always leave the tool menu with the MENU button. NOTE!
Functions marked with * indicate that the symbol for the function is displayed on the control panel even if the
accessory is not installed!
3
2
5
1
1. Arrow symbols
Step between the various tool fields by
pressing the up or
down arrow symbols. You can always
leave the tool menu with
the MENU button.
2. Clock
The clock must be set if automatic night-
time mode or automatic start is to be used.
If 12V voltage is lost, the clock will be reset
and correct time will no longer be dis-
played. This is prevented with an optional
AA battery backup.
3. Automatic night-time mode
This function is used when you want to
program the central heating to automati-
cally lower the temperature at night and
raise the temperature in the morning.
4. Starting the boiler automatically
This function is used to start the boiler
automatically at a later point of time. With
automatic start, the boiler works for 24
hours and then stops. After that, it repeats
the automatic start once a week; at the
same day and time, as long as the function
is activated. For automatic start to function,
the On/Off button must be set in the OFF
position.
14
6
4
7
8
11
5. Constant pump operation
Cont.: With this function selected the pump
is permanently on. (NOTE, this function
limits the supply of hot water, particularly
when there is a low heating requirement)
Therm: With this function selected the
pump is controlled by the panel/room sen-
sor. This is the normal operating mode for
heating the vehicle and obtaining a nor-
mal supply of hot water. Factory setting is
Therm.
6. *Pump speed
The circulation pump's capacity can be
remote controlled from the panel. NOTE!
A pump with remote control must be
installed in order that this function can
be used (see the manual for the vehicle,
boat or building).
7. Offset (temperature adjustment)
Using this function, you can calibrate the
temperature on the panel if you notice that
the temperature (the stabilised room tem-
perature) is not the same as the tempera-
ture shown on the panel. This also applies
to outdoor temperature.
9
10
13
12