10.3 fi nishing with non-combustibles
WARNING
!
Non-combustible fi nish material must not project more than 4" (101.6mm) from the face of the screen/barrier.
If greater projections are desired, increase the clearance to the sides, bottom and top by 2" (50.8mm) for
every additional 1" (25.4mm) of projection. If using an optional surround, the same rules applies, starting from
the top of the surround. Ensure clearances are maintained for surround removal, as it must lift off of appliance
for maintenance.
3"(76.2mm)
2" (50.8mm)
0" (0mm)
DOOR WITH
SAFETY
BARRIER
6" (152.4mm)
5" (127mm)
4" (101.6mm)