Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.50 FOR VENTED GAS FIREPLACES.
HD81-1
RIVER ROCK / STONE
BURNER ASSEMBLY
SAFETY INFORMATION
WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier,
call the fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
Phone (705)721-1212 • Fax (705)720-9081 • www.napoleonfi replaces.com • hearth@napoleonproducts.com
$10.00
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
B81NS
NATURAL GAS
B81PS
PROPANE
WARNING
!
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
1.33A
EN
FR
PG
9
C E R T I F I E D
W415-0808 / D / 11.04.16

Publicité

loading

Sommaire des Matières pour Napoleon B81NS

  • Page 1 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)720-9081 • www.napoleonfi replaces.com • hearth@napoleonproducts.com $10.00...
  • Page 2 TABLE OF CONTENTS NOTE: The camera icon indicates video tutorials are available as additional reference, visit http://mynapoleon.napoleonproducts.com/download/index/44/1 GENERAL INFORMATION INSTALLATION ACCESS PANEL BURNER ASSEMBLY BULKHEADS NIGHT LIGHT™ INSTALLATION PORCELAIN BASE INSTALLATION BURNER COVER INSTALLATION ROCK INSTALLATION ADJUSTMENT FLAME CHARACTERISTICS VENTURI ADJUSTMENT REPLACEMENTS B81S OVERVIEW NOTE: Changes, other than editorial, are denoted by a line in the margin.
  • Page 3 BULKHEADS NOTE: Bulkhead covers need to be removed. PRIMARY BURNER Connect the gas fl ex lines and the pilot line DOTS to the gas bulkheads located under the valve access opening. Be sure to match up the gas manifold marked with a dot with the center bulkhead, also marked with a dot.
  • Page 4 PORCELAIN BASE INSTALLATION INSTALL IN THE FOLLOWING ORDER: Side porcelain panels or brick panels must be installed prior to porcelain base cover plates. For side porcelain panel installation see “PRP81 PORCELAIN REFLECTIVE RADIANT PANEL” leafl et and for brick panel PORCELAIN installation see “GD844KT DECORATIVE COVER PLATE...
  • Page 5 ROCK INSTALLATION WARNING REAL ROCKS MUST NOT BE USED IN THIS APPLIANCE. HEAT WILL CAUSE THEM TO EXPLODE. Position the rocks in front of the center burner Position a few large rocks randomly along the tube, ensure not to cover burner ports. front, making sure not to cover burner ports.
  • Page 6 3.0 ADJUSTMENT FLAME CHARACTERISTICS It is important to periodically perform a visual check of the pilot PILOT ELECTRODE and burner fl ames. Compare them to the illustration provided. If BURNER any fl ames appear abnormal, call a service person. 3/8” - 1/2” (9.5mm - 12.7mm) FLAME SENSOR...
  • Page 7 W415-0808 / D / 11.04.16...
  • Page 8 napoleonproducts.com...
  • Page 9 être converti à d’autres gaz, sauf si une trousse de conversion est utilisée. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 705-721-1212 • Télécopieur 705-720-9081 • www.napoleonfoyers.com • hearth@napoleonproducts.com 1.33A...
  • Page 10 TABLE DES MATIÈRES NOTE: L'icône du camera indique que les vidéos sont disponibles comme une référence supplémentaire, visitez http://mynapoleon.napoleonproducts.com/download/index/44/1 INFORMATION GÉNÉRALE INSTALLATION PANNEAU D’ACCÈS ASSEMBLAGE DU BRÛLEUR RACCORDS INSTALLATION DE LA LUMIÈRE DE VEILLE INSTALLATION DE LA PLAQUE DE RECOUVRMENT EN PORCELAINE INSTALLATION DU COUVERCLE DU BRÛLEUR INSTALLATION DES ROCHES RÉGLAGES...
  • Page 11 RACCORDS NOTE : Les couvercles des raccords doivent être retirés. BRÛLEUR Branchez les conduites de gaz fl exibles et la PRIMAIRE conduite de la veilleuse aux raccords de gaz POINTS situés en dessous de l’ouverture d’accès de la soupape. Assurez-vous de faire correspondre le collecteur de gaz marqué...
  • Page 12 INSTALLATION DE LA PLAQUE DE RECOUVRMENT EN PORCELAINE FAITES L’INSTALLATION SELON L’ORDRE SUIVANT: Les panneaux de porcelaine ou de brique latéraux doivent être installés avant les plaques de recouvrement en porcelaine. Pour l’installation du panneau de porcelaine latéral, voir le feuillet « PANNEAUX RÉFLECTEURS RADIANTS EN PORCELAINE PRP81 »...
  • Page 13 INSTALLATION DES ROCHES AVERTISSEMENT NE PAS UTILISER DE VRAIES ROCHES DANS CET APPAREIL. LA CHALEUR LES FERA EXPLOSER. Placez les roches en avant du tube du Placez quelques grosses roches de façon brûleur central en vous assurant de ne pas aléatoire le long du devant, en vous assurant couvrir les orifi...
  • Page 14 3.0 RÉGLAGES CARACTÉRISTIQUES DE LA FLAMME Il est important d’effectuer périodiquement une inspection visuelle de la fl amme de la veilleuse et du brûleur. Comparez-les à ces illustrations. Si des fl ammes paraissent anormales, ÉLECTRODE VEILLEUSE contactez un technicien de service. 3/8”...
  • Page 15 W415-0808 / D / 11.04.16...
  • Page 16 napoleonproducts.com...

Ce manuel est également adapté pour:

B81ps