3.5 Technical data
Filter data is for standard filters. Other filters may be equipped.
Table 3.1 Technical data
FlexPAK DX
Power
Mains voltage/frequency
Maximum flow
Flow at -15 kPa
Flow at -20 kPa
Maximum vacuum
Filter area
Weight
Inlet/outlet diameter (flanged)
Sound level
Ambient temperature range
Process air temperature
Relative humidity
Compressed air
Material recycling
Control filter area
Control filter material
Maximum installation altitude
Corrosion class according to ISO
12944-2
Supply voltage to external equip-
ment
Protection class
FlexPAK DX
18,5 kW (25 hp)
400 V±10%/50–60 Hz
3
1300 m
/h (765 cfm)
3
1000 m
/h (588 cfm)
3
800 m
/h (470 cfm)
-35 kPa (-5,1 psi)
2
6 m
(64,5 sqft)
454 kg (1000 lb)
150/160 mm (7,87/6,29")
70 dB(A)
0 – +40 °C (32–104 °F)
0 – +60 °C (32–140 °F)
Max. 85%
6–7 bar (87–102 psi)
93,6% per weight
1x12 m² (1x129 sqft)
Polyester
1000 m above sea level
C2 according to ISO 12944-2
24 VDC ±15%
IP42
21,5 kW (29 hp)
460 V±10%/50–60 Hz
3
1300 m
/h (765 cfm)
3
1000 m
/h (588 cfm)
3
800 m
/h (470 cfm)
-35 kPa (-5,1 psi)
2
6 m
(64,5 sqft)
454 kg (1000 lb)
150/160 mm (7,87/6,29")
70 dB(A)
0 – +40 °C (32–104 °F)
0 – +60 °C (32–140 °F)
Max. 85%
6–7 bar (87–102 psi)
93,6% per weight
1x12 m² (1x129 sqft)
Polyester
1000 m above sea level
C2 according to ISO 12944-2
24 VDC ±15%
IP42
EN