outdooR unit
·
If there is an awning above the outdoor unit to protect the appliance from direct sunlight or rain,
make sure that it does not limit the heat radiation from the condenser.
·
Make sure that the clearance behind the appliance and to the left of the appliance measures more
than 30 cm. The clearance in front of the appliance must be greater than 100 cm and more than
60 cm at the connecting side (to the right of the appliance).
·
In addition, the floor clearance should be 20 cm so that the condensation water can drain during
heating operation in the winter without a problem.
·
No objects may be present in the area of air intake and air outlet openings.
·
Take the weight of the appliance into consideration and select a location without interference from
noise and vibration.
·
Select a location where noise and warm air will not disturb your neighbour.
·
Do not install the appliance in a light well because there will be no air exchange.
ROOF INSTALLATION
·
If the unit is to be mounted on a roof, make sure that it is in a level position and that the roof can
bear the weight of the outdoor unit.
·
Make sure that the roof structure and anchoring is suitable for this outdoor appliance.
·
Consult the local authorities to mount the appliance on the roof.
·
Take the subsequent noise and vibration into consideration before installing the appliance on a roof
or in an attic.
·
The appliance must provide easy access for service at all times.
·
Install the appliance on a sloped roof so that it can later be serviced without having to step onto
the sloped roof.