Troubleshoot Symptoms; Test F: Not Cooling - Not Turning On - Norcold DE0041 Serie Manuel D'entretien

Réfrigérateurs à compresseur
Masquer les pouces Voir aussi pour DE0041 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshoot Symptoms

Test F: Not Cooling - Not Turning On

Series DE/EV0041, Series DE/EV0061, DC0061
Complete the "Diagnostic Pre-Checks."
Remove refrigerator from enclosure,
but keep a power supply (either AC
or DC) connected.
Any wires
YES
disconnected
from
terminals?
NO
Turn refrigerator ON. Both green
"ON" indicator light and interior light
should come on.
YES
Do lights
come on?
NO
Is unit
YES
connected to
DC power?
NO
With thermostat in the "OFF" position,
use a DVOM to check input voltage.
The DC voltage must be higher than
cut-in voltage for the desired voltage
input (12/24 VDC) or within
specifications for 120 VAC/240 VAC.
See "Specifications - Voltage
Requirements" section.
Is input
NO
voltage
correct?
YES
Continued on next page.
Refer to "Wiring Diagram." Connect wire.
Test unit.
Examine DC fuse. Replace if necessary.
Correct input voltage. Test unit.
18
www.norcold.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ev0041 serieDc0061De0061 serieEv0061 serie