Test L: Refrigerator Defrosts

The refrigerator cools to thermostat setting but does not restart until
thawing begins.
If the refrigerator exhibits this symptom, contact Norcold Customer
Service (1-800-543-1219) or the OEM Cutomer Relations for the
appropriate replacement parts.
www.norcold.com
Complete the "Diagnostic Pre-Checks."
Remove refrigerator from enclosure,
but keep a power supply connected.
Bypass the thermostat wires:
- Red with white tracer
- Red with blue tracer
Allow the unit to run for eight hours.
Did the unit
maintain
temperature?
NO
Replace the cooling unit.
Replace the thermostat and
the DC power cord.
YES