Snap-On EEWB334A Manuel Opérateur page 114

Masquer les pouces Voir aussi pour EEWB334A:
Table des Matières

Publicité

114
All manuals and user guides at all-guides.com
User Code
Code C0
Setting the factory-adjusted modes of operation
F
(
5.2.2)
0* =
1 =
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C1
Selecting the resolution of unbalance readings in
1 or 5 g, or 0.05 or 0.25 oz increments
0* =
1 =
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C2
Selecting suppression of minor unbalance
readings
0 =
1* =
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C3
Selecting unbalance readings in grammes or
ounces, active when the machine is switched on
0* =
1 =
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C4
Electrical compensation of residual unbalance, if
any, in the clamping means
Measurement with increased precision (this mode
cannot be transferred into the permanent memory).
Compensation has to be cancelled and carried out
* = Factory adjusted mode
No action
Set default values
(state 1 is only shown briefl y)
5 g (0.25 oz) increments
1 g (0.05 oz) increments
Suppression off
Suppression on
Readings in grammes
Readings in ounces