7.1. Adjustment of the Spray Gun Inlet Pressure
• Pull the trigger fully and adjust the spray gun inlet pressure (see
chapter 2) following instructions of one of the followig sections ([3-1],
[3-2], [3-3] to [3-4]), then release the trigger.
• For [3-3] and [3-4], the air micrometer [1-13] must be fully open/in a
vertical position.
• If the required gun supply pressure is not present, increase the pres-
sure in the compressed air circuit. Too high of a pressure will result in
excessive trigger-pull resistance.
[3-1] SATA adam 2 (accessory / accurate method).
[3-2] Separate analogue gauge with regulation device (accessory).
[3-3] Separate analogue gauge without regulation device (accesso-
ry).
[3-4] Pressure regulation at the compressed air circuit (most inaccu-
rate method).
7.2. Adjustment of the Material Flow
und [4-4] - material flow control fully opened
With the material flow control fully opened, the wear of the fluid tip and
paint needle is reduced to a minimum. Please select the correct nozzle
size depending on the material to be applied and the required applica-
tion speed.
7.3. Adjustment of the Spray Fan Pattern
• Adjust flat fan (factory setting) [5-1].
• Adjust round fan [5-2].
7.4. Painting
Fully pull trigger for painting [6-1]. Operate spray gun according to [6-2].
Maintain spray distance as described in chapter 2.