Warranty: Refer to standard Hilti terms and conditions of sale for warranty information.
Failure to observe these installation instructions, use of non-Hilti anchors, poor or questionable concrete conditions,
or unique applications may affect the reliability or performance of the fastenings.
Product Information
;
– Always keep this instruction for use together with the product.
– Ensure that the instruction for use is with the product when it is given to other persons.
– Safety Data Sheet: Review the SDS before use.
– Check expiration date: See expiration date imprint on foilpack manifold (month/year). Do not use expired product.
– Foil pack temperature during usage: +5 °C to 40 °C / 41 °F to 104 °F.
– Conditions for transport and storage: Keep in a cool, dry and dark place between +5 °C to 25 °C / 41 °F to 77 °F.
– For any application not covered by this document / beyond values specified, please contact Hilti.
– Partly used foil packs must be used up within one week. Leave the mixer attached on the foil pack manifold in the
dispenser and do not retract the pistons! Remove the air pressure hose andr store under the recommended storage
conditions. If reused, attached a new micer and discard the initial quantity of anchor adhesive.
WARNING
Improper handling may cause mortar splashes. Eye contact with mortar may cause irreversible eye damage!
– Always wear tightly sealed safety glasses, gloves and protective clothes before handling the mortar!
– Never start dispensing without a mixer properly screwed on.
– When using an extension hose: Discard of initial mortar flow must be done through supplied mixer only (not through
the extension hose).
– Attach a new mixer prior to dispensing a new foil pack (snug fit).
– Caution! Never remove the mixer while the foil pack system is under pressure.
– Use only the type of mixer supplied with the adhesive. Do not modify the mixer in any way.
– Dropping foil packs, also foil packs already inserted into the foil pack holder, is likely to cause damage leading to mal
function.
– Never use damaged foil packs and/or damaged or unclean foil pack holders.
Poor load values / potential failure of fastening points due to inadequate borehole cleaning. The boreholes must be dry
and free of debris, dust, water, ice, oil, grease and other contaminants prior to adhesive injection.
– Hilti hollow drill bits TE-CD, TE-YD must be used in conjunction with a properly maintained Hilti vacuum cleaner with
model and suction capacity (volumetric flow rate) as specified in the accessory table.
– For blowing out the borehole - blow out with oil free air until return air stream is free of noticeable dust.
– For flushing the borehole - flush with water line pressure until water runs clear.
– Important! Remove all water from the borehole and blow out with oil free compressed air until borehole is completely
dried before mortar injection (not applicable to hammer drilled hole in underwater application).
– Inject adhesive immediately after cleaning the borehole. If not, water may come into the borehole when using wet
base material.
Ensure that boreholes are filled from the back of the boreholes without forming air voids.
– If necessary, use the accessories / extensions to reach the back of the borehole.
– For overhead applications use the overhead accessories HIT-SZ / IP and take special care when inserting the faste-
ning element. Excess adhesive may be forced out of the borehole. Make sure that no mortar drips onto the installer.
– If a new mixer is installed onto a previously-opened foil pack, the first trigger pulls must be discarded.
Due to the heat generation during curing, metal element (rod) must be set within the allowed working time or wood (the
base material) may be negatively effected.
Not adhering to these setting instructions can result in failure of fastening points.