EUROM HKG 10-BE Manual D'utilisation page 24

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10. Wait until the ventilator is running steadily and stable. Now press the right-
hand button of the gas valve and keep it pressed down for 10 seconds. Then
with your left hand simultaneously press
the ignition button a few times to ignite the
device (Diagram 4).
11. After the gas starts burning, keep the gas
valve pressed in for another 15 seconds.
After that, you can let go and the gas will
burn continuously (Diagram 5).
12. To switch off the device, close the gas tap
of the gas bottle and wait until the flame
goes out. Now switch the power switch to O
(off) and remove the plug from the socket.
Finally, disconnect the pressure regulator
from the gas bottle.
Attention! The device will remain hot for a
while after use. Always remove the plug from the socket when the unit is not in
use.
13. If you have to change the gas bottle or want to use the device after a period of
storage, you must repeat the entire process, including the gas leakage test.
Attention!
If you have tried to start the device according to the procedure described above
and that does not work after three attempts to ignite it, don't try it again. Due to
the high gas concentration, there is now an explosion hazard! Contact your dealer
to find out the reason for the malfunction.
Make sure when you install the gas bottle that the gas hose is not bent or kinked.
Avoid twisted and tensile stress. This can damage it and gas leakage can occur!
Always use the correct, supplier-provided pressure regulator and gas hose.
If you have questions about the gas hose, contact your supplier. A length of 1.5
metres is advised.
Gas leakage test
To rule out the possibility of damage during transport or due to high pressure, wear
and tear, etc., a complete gas leakage test must be performed during installation,
after changing a gas bottle and after a period of storage. All leakage inspection
must be performed with a soap solution, never with fire! Do not smoke
during the inspections. When there is gas leakage, immediately close the gas tap
on the gas bottle (be alert for the odour!) and remove the equipment far from other
sources of heat, fire and sparks.
 Perform the inspection with a full gas bottle.
 Unplug it, switch the power switch to O (off), close the gas supply.
 Make a soap solution with one part liquid soap and one part water.
 Apply the soap solution to the entire gas transport system, especially on the
connections, with a spray bottle, brush or cloth.